Very good documentation for the Grundig 2077 model (as well as similar 800/900/1000 series radios). The first two pages are a summary of reception specifications and output capability. The third page is the tuner dial indicator and dial cord routing diagram. the final ~5 pages are the schematics for the various models (including 2077). The scan quality of the schematics are good, adn can be easily read if zoomed in. The documents are in German, not English as stated. It would have been nice to have the tuning sequence and settings, and some trouble shooting materials... or component and wiring map.
 ;
Perfect like it was descriped, Perfect like it was descriped
 ;
Very good detail, all pages clear, exactly what I needed
MZ-N510CK SECTION 4 TEST MODE
Outline
� This set provides the Overall adjustment mode that allows CD and MO discs to be automatically adjusted when in the test mode. In this overall adjustment mode, the disc is discriminated between CD and MO, and each adjustment is automatically executed in order. If a fault is found, the system displays its location. Also, the manual mode allows each individual adjustment to be automatically adjusted. � Operation in the test mode is performed with the set. A key having no particular description in the text, indicates a set key.
Operation in Setting the Test Mode
� When the test mode becomes active, first the display check mode is selected. � Other mode can be selected from the display check mode. � When the test mode is set, the LCD repeats the following display.
Set LCD display
Setting Method of Test Mode
There are three different methods to set the test mode: 1 Short SL803 (TEST) on the MAIN board with a solder bridge (connect pin <zx. of IC801 to the ground). Then, turn on the power. � MAIN Board (Side B) �
All lit
All off
Microcomputer version display
00 8
V1.200
� When the X key is pressed and hold down, the display at that time is held so that display can be checked.
Releasing the Test Mode
For test mode set with the method 1: Turn off the power and open the solder bridge on SL803 (TEST) on the MAIN board.
Note: Remove the solders completely. Remaining could be shorted with the chassis, etc.
For test mode set with the method 2 or 3: Turn off the power.
SL803 (TEST)
2 In the normal mode, turn on the [HOLD] switch. While pressing the [GROUP] key press the following order:
>t>t.t.t>t .t>t.tXtX
3 In the normal mode, turn on the [HOLD] switch on the set. While pressing the xCANCEL/CHG key on the set, press the keys on the remote commander with the following order : >t>t.t.t>t . t > t . t --t -Note: If electrical adjustment (CD and MO overall adjustment) has not been finished completely, �NV Error� is displayed on LCD of the set.