Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
When I purchased this manual I had my doubts regarding the quality as the price was so reasonable as compared to other outlets.
The manual itself is of high standard the print is very clear as are the diagrams. Obviously with the diagrams one has to zoom in otherwise it is to small to be able to read.
Overall I am very pleased with the company who delivered as they said and with the manual they supplied.
I occasionally require a manual and now having registered with this company I shall order from them in the future.
 ;
I was at first dubious about payiong for downloaded manuals but having done so, I was extremely impressed with quality of the two manual I ordered, well worth the small price I paid.
I would highly recommend these to my friends.
 ;
reasonable price for the schematic - the service is perfect, all as expected and pointed by instructions - good scan of the original plans - thank you!
 ;
Manual was just as described!!! I odered it and in less than a day was able to download it and the text was clear and pages were all complete just as the original manual was. Purcashed this for a friend and they were more than happy. Perfect all around!
 ;
Excellent service and prompt delivery. But it's not a manual - only 4 pages wiring diagrams.
Thanks.
Ver 1.5 2001. 01
SECTION 5 ELECTRICAL ADJUSTMENTS
PRECAUTIONS FOR ADJUSTMENT
1) Perform all adjustments in the order given in the test mode. After adjusting, exit the test mode. 2) Use the following tools and measuring instruments. � Test CD TDYS-1 (Part No. : 4-963-646-01) � SONY MO disc available on the market � Laser power meter LPM-8001 (Part No. : J-2501-046-A) � Oscilloscope (Frequency band above 40 MHz. Perform the calibration of probe first before measuring.) � Digital voltmeter 3) Unless specified othewise, supply DC 3V from the DC IN 3V jack. 4) Swtich, knob positions HOLD switch .............. OFF AVLS switch ................ NORM
MO TRAVERSE ADJUSTMENT
Connection :
oscilloscope MAIN board TP5980 (TE) AP5430 (VC)
Adjustment Method : 1. Set the servo mode of the test mode (Mode : 000). 2. Press the ( key, and set the MO test adjustment mode (Mode : 030) using the VOLUME + or � key. 3. Press the = or + key and move the optical pick-up to the center circumference. 4. Insert any MO disk available on the market. 5. When the ( key is pressed, the MO read FE balance adjustment mode (Mode : 032) will be set after MO focus search adjustment mode (Mode : 031). 6. Press the P key to perform automatic adjustment, and check that the traverse waveform is symmetrical at the top and bottom. 7. Slide the REC key and set the MO write FE balance adjust ment mode (Mode : 034). 8. Press the P key to perform automatic adjustment, and check that the traverse waveform is symmetrical at the top and bottom.
LASER POWER CHECK
Connection :
laser power meter
Optical pick-up objective lens
(Traverse waveform)
digital voltmeter MAIN board AP5117 (VCC) AP574 (LDI0)
A 0V B Specification : A = B, C = 1.0 Vp-p > C
Adjustment Method : 1. Set the servo mode of the test mode (Mode : 000). 2. Press the ( key, and set the laser power adjustment mode (Mode : 020) using the VOLUME + or � key. 3. Press the = key and move the optical pick-up to the inner most circumference. 4. Open the cover and set the laser power meter on the objective lens of the optical pick-up. 5. Press the ( key, and set the laser CD/MO read adjustment mode (Mode : 021). 6. Check that the laser power meter reading is 0.85 ± 0.085 mW. 7. Check that the voltage between AP5117 (VCC) and AP574 (LDI0) at this time is below 44 mV. 8. Press the ( key, and set the laser MO write adjustment mode (Mode : 022). 9. Check that the laser power meter reading is 6.8 ± 0.68 mW. 10. Press the P key to finalize the adjustment data. 11. Check that the voltage between AP5117 (VCC) and AP574 (LDI0) at this time is below 80 mV. 12. Press the p key. 13. Exit the test mode. Adjustment Location : See page 19.
9. Check that the traverse level at this time is above 1.0 Vp-p. 10. Press the p key. 11. Exit the test mode.
Note) Using a recorded disk in this adjustment will erase the data.
Adjustment Location : See page 19.