MZ-S1
23) Adjust with the [VOL +] key (adjusted value up) or [VOL --] key (adjusted value down) so that the adjusted value becomes 5B. 24) Press the X key to write the adjusted value. 25) Select manual mode of the test mode, and set item number 777 (see page 16).
Set LCD display
37) Select manual mode of the test mode, and set item number 865 (see page 16).
Set LCD display
865
###: Address **: Adjusted value
###S**
**: Adjusted value
777
AD **
26) Adjust with the [VOL +] key (adjusted value up) or [VOL --] key (adjusted value down) so that the adjusted value becomes 7B. 27) Press the X key to write the adjusted value. 28) Select manual mode of the test mode, and set item number 778 (see page 16).
Set LCD display
38) Adjust with the [VOL +] key (adjusted value up) or [VOL --] key (adjusted value down) so that the adjusted value becomes 2C. 39) Press the X key to write the adjusted value. 40) Select manual mode of the test mode, and set item number 866 (see page 16).
Set LCD display
866 778
**: Adjusted value
###S**
AD **
###: Address **: Adjusted value
29) Adjust with the [VOL +] key (adjusted value up) or [VOL --] key (adjusted value down) so that the adjusted value becomes 7D. 30) Press the X key to write the adjusted value. 31) Select manual mode of the test mode, and set item number 779 (see page 16).
Set LCD display
41) Adjust with the [VOL +] key (adjusted value up) or [VOL --] key (adjusted value down) so that the adjusted value becomes B9. 42) Press the X key to write the adjusted value. 43) Select manual mode of the test mode, and set item number 867 (see page 16).
Set LCD display
779
**: Adjusted value
AD **
###: Address **: Adjusted value
867
###S**
32) Adjust with the [VOL +] key (adjusted value up) or [VOL --] key (adjusted value down) so that the adjusted value becomes 7F. 33) Press the X key to write the adjusted value. 34) Select manual mode of the test mode, and set item number 781 (see page 16).
Set LCD display
44) Adjust with the [VOL +] key (adjusted value up) or [VOL --] key (adjusted value down) so that the adjusted value becomes C9. 45) Press the X key to write the adjusted value. 46) Select manual mode of the test mode, and set item number 868 (see page 16).
Set LCD display
781
**: Adjusted value
AD **
###: Address
868
###S**
**: Adjusted value
35) Adjust with the [VOL +] key (adjusted value up) or [VOL --] key (adjusted value down) so that the adjusted value becomes 81. 36) Press the X key to write the adjusted value.
47) Adjust with the [VOL +] key (adjusted value up) or [VOL --] key (adjusted value down) so that the adjusted value becomes 80. 48) Press the X key to write the adjusted value.