MACKIE HR824 26 pages English-only Service Manual contains:
1) HR824 technical overview with the description of front and rear panel switches.
2) HR824 specs
3) Block Diagram
4) Wiring Diagram
5) Packaging management
6) Spare part & final assembly list (for PCB rev A and B) + exploded view
7) Test Procedures (where, how to measure voltage...) including Test Point diagram on the PCB.
8) IC and Transistor charts.
Excellent guide: very clear, good scan quality enabling us to print readable diagram :-)
Note:
Mackie HR824 make extensive use of surface mount devices (SMD). Service on the HR824 must
only be undertaken by experienced service technicians with the right tools, experience and patience to perform surface mount rework when needed.
1-A. Preliminary/Final Checking and Alignment of Tape Path
Purpose: To make sure that the tape path is well stabilized. Symptom of Misalignment: If the tape path is unstable, the tape will be damaged. Note: Do not use an Alignment Tape for this procedure. If the unit is not correctly aligned, the tape may be damaged. 1. Playback a blank cassette tape and check to see that the tape runs without creasing at Guide Rollers [2] and [3], and at points A and B on the lead surface. (Refer to Fig. M3 and M4.) 2. If creasing is apparent, align the height of the guide rollers by turning the top of Guide Rollers [2] and [3] with a Guide Roller Adj. Screwdriver. (Refer to Fig. M3 and M5.)
Guide Roller [2] Guide Roller [3]
3. Check to see that the tape runs without creasing at Take-up Guide Post [4] or without snaking between Guide Roller [3] and ACE Head. (Fig. M3 and M5) 4. If creasing or snaking is apparent, adjust the Tilt Adj. Screw of the ACE Head. (Fig. M6)
Azimuth Adj. Screw
ACE Head Flat Screwdriver
Tilt Adj. Screw
Fig. M6
1-B. X Value Alignment
Purpose: To obtain maximum PB FM envelope signal at the preset position of the Tracking Control Circuit, align the Horizontal Position of the ACE Head. Symptom of Misalignment: If the Horizontal Position of the ACE Head is not properly aligned, maximum PB FM envelope cannot be obtained at the preset position of the Tracking Control Circuit. 1. Connect the oscilloscope to TP (C-PB and CTL) on the Main CBA. Use TP (RF-SW) as a trigger. 2. Playback the Gray Scale of the Alignment Tape (FL8N --- 2 head model, FL8NW --- 4 head model) and confirm that the PB FM signal is present. 3. Set the Tracking Control Circuit to the preset position by pressing CH UP button on the remote control unit then �PLAY� button on the unit. (Refer to note on bottom of page 2-3-4.)
ACE Head
A
B Take-up Guide Post [4]
Fig. M3
Lead Surface of Cylinder
Tape
Fig. M4
4. Use the Flat Screwdriver so that the PB FM signal at TP (C-PB) is maximum. (Fig. M6)
Correct
Guide Roller Tape
Incorrect
Tape
Take-up Guide Post
Fig. M5
2-3-3