It's great to be able to obtain a precious technical information for a real old equipment. The one I got helps me a lot in the area of wiring diagram to repair my antique. PDF gave me clear enough information to find out thr details. Thanks for giving me the oppotunity to be able to access to almost vanished informations.
;
Another excellent aquisition. Fine detailed manual. Thanks
;
Good quality for the scan, complete, but as usual for Tascam, not so comprehensive !
;
great manual readable & easy to downlaod to be recommanded
NN-P795 NN-P794SFR
4 SIMPLE WAY OF H.V. INVERTER/MAGNETRON TROUBLESHOUTING
Purpose: Simple way (3/23 seconds rule) of identifying whether it�s Magnetron, Inverter, or others. Set-up: The unit under question is connected through the Ammeter as shown below.
Procedure: Follow the matrix table below to identify the problem source. Note: Do not replace both Inverter board and Magnetron simultaneously and automatically without going through this procedure.
Power will: Ammeter reading is: Shut off in 23 seconds 1. Between 0.5A and 1.0A. after �Start�. 2. Between 1.0A and 2.0A. To do: Remedy: Check and repair open magnetron circuit Open magnetron wiring between Inverter and magnetron terminal. Check continuity of D702 in Inverter PCB.
1. D702 shorted
Shut off in 3 seconds 1. Less than 0.5A after �Start�
Replace H.V.Inverter (F606Y6G00AP/F606Y6G00CP) 2. D702 is OK Replace magnetron Check open circuit: Latch Switch, DPC, Replace defective component(s), or Power Relay and CN701 correct switch, cables and connectors.