Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Quick site processing. A complete and very useful manual with all details. Thank you!
 ;
Quick service response. A useful and very rare service manual with all details. I recomend this service.
 ;
I ordered this manual sometime in the afternoon and I received it on my e-mail the same evening.
This is a fantastically good and properly scanned copy of the original manual. All pages are of the same scale and they overlap each other. It means that you can print the manual and easily make it as a convenient paper manual.
The content of the manual is fantastic. Alignment descriptions, PCB layouts and elementary diagrams are explicit and precise. I immediately found what I was looking for. Thanks to this manual and Owner-Manuals.com my amplifier is alive again. Many thanx indded!
 ;
The manual was well-scanned and easy to read. As an added bonus, the Operator's Manual was bundled with the Service Manual!
I'd definitely use owner-manuals.com again.
 ;
Finally, i found one website, where i can download this service manual , and fix my hifi. The service manual is very good, and easy to download and to print.
NN-P795 NN-P794SFR
4 SIMPLE WAY OF H.V. INVERTER/MAGNETRON TROUBLESHOUTING
Purpose: Simple way (3/23 seconds rule) of identifying whether it�s Magnetron, Inverter, or others. Set-up: The unit under question is connected through the Ammeter as shown below.
Procedure: Follow the matrix table below to identify the problem source. Note: Do not replace both Inverter board and Magnetron simultaneously and automatically without going through this procedure.
Power will: Ammeter reading is: Shut off in 23 seconds 1. Between 0.5A and 1.0A. after �Start�. 2. Between 1.0A and 2.0A. To do: Remedy: Check and repair open magnetron circuit Open magnetron wiring between Inverter and magnetron terminal. Check continuity of D702 in Inverter PCB.
1. D702 shorted
Shut off in 3 seconds 1. Less than 0.5A after �Start�
Replace H.V.Inverter (F606Y6G00AP/F606Y6G00CP) 2. D702 is OK Replace magnetron Check open circuit: Latch Switch, DPC, Replace defective component(s), or Power Relay and CN701 correct switch, cables and connectors.
10
|
|
 |
> |
|