|
There are currently no product reviews.
 ;
Very quality copy of original service manual, which contains the circuit diagrams, PCB and lists of components, well as recommendation for calibration procedures of device, also everything else, that need for repair, tuning and use this oscilloscope.
All presented copies have high-resolution, so you can view all in detail.
This manual will very useful for simple owners and for repairers.
I recommend these manual, because myself is owner of Philips PM3216 and I need sometimes servicing these oscilloscope (principally calibrating).
Also, these document is an example of excellent design of technical documentation.
 ;
Excellent printing quality.
A complete and very usefull service manual with all details.
GREAT SERVICE AT VERY LOW PRICE!
A+++++++++++++++++++++++++
 ;
manual excelente completo , diagramas y esquemas bien presentados y buena calidad de imagen.
 ;
muy buen manual completo de buena calidad de impresion preciso y detallado , muy útil para la reparación.
 ;
The service manual is a good quality scan of the Panasonic NV-850, which is electrically identical to the Philips VR 6920, but mecanically just nearly.
,.-.._
B. Scanner Drive Assembly
1. Routing the Mirror Drive Cable 1) Loosen the two fixing screws shown in Figure
4-205. 2) Turn the adjusting screw to move the pulley@ to the right. 3) Move the No. 1 and No. 2 mirror mounts fully to the front. 4) Route the cable with the numbered order provided in Figure 4-205. at number lead the cable at the bottom @, of the pulley. at number g:, wind the cable five times clockwise from bottom to top.
at number @I,,lead cable at the top of the pulley. 5) Adjust the tension of the cable; see �Adjusting the Tension of the Mirror cable:� 6) Adjust the position of the mirror; see �Adjusting the Position of the Mirror.�
2.
Adjusting the Tension of the Mirror Drive Cable
To adjust the tension of the mirror drive cable, loosen the fixing screw, and turn the adjusting screw to change the position of the pulley 0. Set the No.1 mirror mount on the home position side, and pull a point between 0 and @ with a spring gauge; Figure 4-205. Make adjustments so that the reading of the gauge is 800 to 900 g when the cable is pulled to the front of the machine by 20 mm.
No.2 mirror mount
No.1 mirror mount
\
Scanner motor
Adjusting screw
Figure 4-205
,/- \
COPVRlGNl CANON INC. 0 l@i
CANON NP305013WO 1991 REV.1 OCT. PWED JAPAN AU IN (IMPRUE JAK�N)
4-9
 $4.99 NP3030 CANON Parts Catalog Parts Catalog only. It's available in PDF format. Useful, if Your equipment is broken and You need t…
|