Panel Alarm
FPC Opened
Panel alarm line go through the edge of the FPC. CHECK POINT FPC cutting at scan side and TCP side.
REWORK We can not rework this.
Panel Grid Opened Alarm Protection
Panel alarm line go through the edge of panel. This case is caused by sulfur issue. CHECK POINT Panel Grid condition. REWORK We can not rework this.
Vs Protection
High Voltage Circuit Broken
Next parts will be broken, Scan Board, Common Board, High Voltage Board, Scan Relay Board. CHECK POINT Fuse on boards, Power HIC, Between NEGA and POSI on scan relay board
8
REWORK Change the Scan, Common board and Scan relay board.
|
|
|
> |
|