Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Je suis audiophile belge, électronicien et créateur d'enceintes acoustiques.
J'ai apprécié la qualité des documents fournis. Ils sont très lisibles, ils peuvent être agrandis sans problème et ils sont complets. Pour moi, c'est parfait. Pour cette qualité, je suis d'accord de payer. Et le système de paiement et d'envoi est simple. Merci, continuez comme cela.
Frédéric
 ;
The cover page was a little scary, very dark but readable. The remainder of the document was better copy and easily readable. Why would I give 5 Stars? (1) PRICE, (2) AUTHENTICITY, It was the real deal, filled with service information, including the specific information I required. (3) PRIVACY, I didn't start to get slammed with spam. (4) EASY TRANSACTION. Painless. (5) COMPLETE, I have found several manuals here, that I could find nowhere else. (6) I will be a repeat customer!
 ;
Well done!!! I found what I need to have, indeed!
Furthermore, due to my hobby is repairing vintage equipments, I added this web site in my desk toolbar because I have in mind to search further service manuals. Thanks a lot www.owner-manuals.com !
Regards, Maurizio
 ;
Again very good service manual, this time very fast download. AAAAA+
 ;
Ckear manual, well reproduced with plenty of overlap on critical pages.
ADJUSTMENT
<TUNER/DECK>
u
TUNER
C.B
.p3r
<TUNER
SECTION> 5. MW Tracking Adjustment (HR) Settings : Test point : TP6(Lch), TP7(Rch) Adjustment location : L981(l/3) ........................................ 603kHz TC941 ........................................... 1404kHz
q q
1. Clock Frequency Check Settings : q Test point: TP2 (CLK) Method: Set to AM 1710kHz(U,LH,HA),MW1602kHz(HR) and check that the test point is 2160kHz f 45 Hz(U,LH,HA), 2052kHz * 45 Hz(HR). 2. AM VT Check (U,LH,HA) Settings : q Test point: TP1 (VT) Method : Set to AM 1710kHz and AM 530kHz and check that the test point is less than8.5V(1710kHz) and more than 0.6V(530kHz).
Method : Setup TC941 to center before adjustment. The level at 603kHz is adjust to max. by L981(l/3). Then the level at 14041cHz is adjust to max. by TC941. 6. SW VT Adjustment (HR) Settings : q Test point: TP1 (VT) Adjustment location : L942 q Method : Set to SW 17.9MHz and adjust L942 so that the test point becomes 7.OV ~ 0.05V. Then set to SW 5.9MHz and check that the test point is more than 0.3V. 7. SW Tracking Adjustment (HR) Settings : q Test point: TP6(Lch), TP7(Rch) Adjustment location : q L941 ............................................... 5,9MHZ TC943 .......................................... 17.9MHz Method: Set up TC943 to center before adjustment. The level at 5.9MHz is adjust to max. by L941. Then the level at 17.9MHz is adjust to max. by TC943.
3. MW VT Adjustment (HR) Settings : q Test point: TP1(VT) q Adjustment location : L981 (3/3) Method: Set to MW 1710kHz and adjust L981(3/3) so that the test point becomes 8.OV + 0.05V. Then set to MW 530kHz and check that the test point is more than 0,3V. 4. AM Tracking Adjustment (U,LH,HA) Settings : q Test point: TP6(Lch), TP7(Rch) q Adjustment location : L981(l/3) ................................ loookHZ(u) L981(l/3) ......................... 999kHz(LH,HA) Method : Set to AM 1000kHz(U),999kHz(LH,HA) and adjust L98 1(1/3) so that the test point is max.
62