|
Who's Online
There currently are 5884 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
The manual was as described. Complete with parts list and technical information. Fast delivery.
;
Simple and fast...
The diagrams are clear and legible; i have been a great help.
The site is very reliable and precise thanks.
;
Very easy site. Great service and quick release for download. Manuals are of good quality.
Joop - The Netherlands
;
Very good manual, in depth and complete. Only criticism is that some of the circuit diagrams are slightly blurry and hard to follow for long periods of time, but this is to be expected. Perfect for any maintenance required. Also contains the wiring diagrams of the control cable for constructing extensions.
;
Received a quick response, material was exactly what it was supposed to be. The service did everything I expected it to do. would use service again.
ELECTRICAL ADJUSTMENT -5/7
<DECK Section> Make the following preparations for DECK section adjustment. Preparations Measuring Equipment: Audio Signal Generator / Attenuator / Wow and Flutter Meter (Frequency Counter) / Oscilloscope / Millivoltmeter / Dummy resistance (6�) Test Tape: TTA-100 / TTA-300 (or TTA-310, 320) / TTA-200 / TTAA602(or equivalent recording and Playback Test Tapes) 10. Tape Speed Adjustment (DECK 2) Requirements � Measuring instrument: Wow and flutter meter (frequency counter) Test tape: TTA-100 (3 kHz) Test point: HP OUT Adjustment point: SFR1 1) Connect the wow and flutter meter to HP OUT of the unit. 2) Insert the test tape (TTA-100) to DECK 2. Play back the middle part of the tape, and adjust SFR1 so that the level 3,000 Hz 5 Hz is monitored. 11. Tape Speed Check (DECK 1) Requirements: Same as the above, 10. 1) Insert the test tape (TTA-100) to DECK 1. Play back the middle part of the tape, and check that the level is ranged within 55 Hz as compared to the speed monitored for DECK 2. 12. Wow and Flutter Check (DECK 1 and DECK 2) Requirements: Same as the above, 10. 1) Connect the wow and flutter meter to HP OUT of the unit. 2) Set the wow and flutter to JIS for INDICATOR and to W RMS (WTD) for mode. 3) Play back the middle part of the test tape (TTA-100), and check that the level ranges under 0.25%. 13. Head Azimuth Adjustment (DECK 1 and DECK 2) Requirements � Measuring instrument: Oscilloscope Test tape: TTA-300 (10 kHz) Test point: TP8 (Lch), TP9 (Rch) Adjustment point: Head azimuth adjustment screw 1) Connect the probe CH1 of the oscilloscope to TP8 (Lch) and CH2 to TP9 (Rch). 2) Set V mode of the oscilloscope to ADD. 3) Insert the test tape (TTA-300) to DECK 1. Forward and play back the middle part of the tape, and adjust the head azimuth adjustment screw so that the waveform achieves its maximum level when 10 kHz is played. 4) After adjustment, secure the screw with glue (1600 B). 5) Apply the above steps 3) and 4) to DECK 2. 14. Playback Frequency Check (DECK 1 and DECK 2) Requirements � Measuring instrument: Millivoltmeter Test tape: TTA-300 (315 Hz / 10 kHz) Test point: TP8 (Lch), TP9 (Rch) 1) Connect CH1 of the millivoltmeter to TP8 (Lch) and CH2 to TP9 (Rch). 2) Insert the test tape (TTA-300) to DECK 1, and play back 315 Hz and 10 kHz. 3) Check that the level of 10 kHz is ranged within 0 315 Hz as a reference. 4) Apply the above steps 2) and 3) to DECK 2. 3 dB compared to the output level of
TP8 TP9
WOW&FLUTTER METER Hz INPUT HP OUT %
OSCILLOSCOPE
OUTPUT CH1 CH2
AC MILLIVOLTMETER
CH1 CH2 TP8 TP9
-39-
$4.99 NSXTR77 AIWA Owner's Manual Complete owner's manual in digital format. The manual will be available for download as PDF file aft…
|
|
|
> |
|