I didn't realise a manual for an early plasma TV such as the one we were gifted could be so easily obtained. No manual was supplied with it, and as senior citizens we were a little puzzled over some aspects of its use. I do not want a listing for your store credit as we are not fairly big computer users. The manual was well organised, as it should be, with its backing of the Pioneer name. The download was prompt and everything worked quite smoothly. Thank you. Gordon.
< DECK SECTION >
11. Tape Speed Adjustment (DECK 2) Settings : � Test tape : TTA�100 � Test point : TP8 (Lch), TP9 (Rch) � Adjustment location : SFR1 Method : Play back the test tape and adjust SFR1 so that the frequency counter reads 3000 Hz ± 5 Hz (FWD). 12. Head Azimuth Adjustment (DECK 1, DECK 2) Settings : � Test tape : TTA�330 � Test point : TP8 (Lch), TP9 (Rch) � Adjustment location : Head azimuth adjustment screw Method : Play back (FWD) the 8 kHz signal of the test tape and adjust screw so that the output becomes maximum. Next, perform on REV PLAY mode. 13. PB Frequency Response Check (DECK 1, DECK 2) Settings : � Test tape : TTA�330 � Test point : TP8 (Lch), TP9 (Rch) Method : Play back the 315 Hz and 8 kHz signals of the test tape and check that the output ratio of the 8 kHz signal with respect to that of the 315 Hz signal is 0 dB ± 5 dB. 14. PB Sensitivity Check (DECK 1, DECK 2) Settings : � Test tape : TTA�200 � Test point : TP8 (Lch), TP9 (Rch) Method : Play back the test tape and check that the output level of the test point is 110 mV ± 3 dB. 15. REC/PB Frequency Response Adjustment (DECK 2) Settings : � Test tape : TTA�602 � Test point : TP8 (Lch), TP9 (Rch) � Input signal : 1 kHz / 8 kHz (LINE IN) (-20VU) � Adjustment location : SFR451 (Lch) SFR452 (Rch) Method : Apply a 1 kHz signal and REC mode. Then adjust OSC attenuator so that the output level at the TP8, TP9 becomes 0 dB (10 mV). Record and play back the 1 kHz and 8 kHz signals and adjust SFRs so that the output of the 8 kHz signals becomes 0 dB ± 1 dB with respect to that of the 1 kHz signal. 16. REC/PB Sensitivity Check (DECK 2) Settings : � Test tape : TTA�602 � Test point : TP8 (Lch), TP9 (Rch) � Input signal : 1 kHz (LINE IN) (0VU) Method : Apply a 1 kHz signal and REC mode. Then adjust OSC attenuator so that the output level at TP8, TP9 becomes 0 dB (100 mV). Record and play back the 1 kHz signals and check that the output is -1 dB ± 3.5 dB.
� 24 �
|
|
 |
> |
|