Who's Online
There currently are 5830 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
very fast detailed and accurate hope to do business again
;
This was precisely what I was looking for. Complete and good quality!
;
This is the ONLY copy of this manual I could find for a realistic price. Even Panasonic could not provide me with one.
The PDF is a very good copy and it helped me diagnose and find the fault with the unit I have.
;
Very complete and well reading drawings. Documentation is essential for successful repairs.Good documentation, with all that is necessary. This manual was what I was waiting with all the information necessary for the repairing I need it for. You must buy it if you want to do repairs or simply understand how it works.
;
Excellent service manual includes everything is need to repair this radio-caseete, how to disassemble, wiring diagram, all , waiting time until the download was only a few hours. I'm going to buy service manuals from here, are cheap and very good.Thank you.
< DECK SECTION >
11. Tape Speed Adjustment (DECK 2) Settings : � Test tape : TTA�100 � Test point : TP8 (Lch), TP9 (Rch) � Adjustment location : SFR1 Method : Play back the test tape and adjust SFR1 so that the frequency counter reads 3000 Hz ± 5 Hz (FWD). 12. Head Azimuth Adjustment (DECK 1, DECK 2) Settings : � Test tape : TTA�330 � Test point : TP8 (Lch), TP9 (Rch) � Adjustment location : Head azimuth adjustment screw Method : Play back (FWD) the 8 kHz signal of the test tape and adjust screw so that the output becomes maximum. Next, perform on REV PLAY mode. 13. PB Frequency Response Check (DECK 1, DECK 2) Settings : � Test tape : TTA�330 � Test point : TP8 (Lch), TP9 (Rch) Method : Play back the 315 Hz and 8 kHz signals of the test tape and check that the output ratio of the 8 kHz signal with respect to that of the 315 Hz signal is 0 dB ± 5 dB. 14. PB Sensitivity Check (DECK 1, DECK 2) Settings : � Test tape : TTA�200 � Test point : TP8 (Lch), TP9 (Rch) Method : Play back the test tape and check that the output level of the test point is 110 mV ± 3 dB. 15. REC/PB Frequency Response Adjustment (DECK 2) Settings : � Test tape : TTA�602 � Test point : TP8 (Lch), TP9 (Rch) � Input signal : 1 kHz / 8 kHz (LINE IN) (-20VU) � Adjustment location : SFR451 (Lch) SFR452 (Rch) Method : Apply a 1 kHz signal and REC mode. Then adjust OSC attenuator so that the output level at the TP8, TP9 becomes 0 dB (10 mV). Record and play back the 1 kHz and 8 kHz signals and adjust SFRs so that the output of the 8 kHz signals becomes 0 dB ± 1 dB with respect to that of the 1 kHz signal. 16. REC/PB Sensitivity Check (DECK 2) Settings : � Test tape : TTA�602 � Test point : TP8 (Lch), TP9 (Rch) � Input signal : 1 kHz (LINE IN) (0VU) Method : Apply a 1 kHz signal and REC mode. Then adjust OSC attenuator so that the output level at TP8, TP9 becomes 0 dB (100 mV). Record and play back the 1 kHz signals and check that the output is -1 dB ± 3.5 dB.