PROCEDURES Press the FF and EJECT keys simultaneously for 3 seconds. Press the FF and EJECT keys simultaneously more twice. Press the EJECT key for 3 seconds.
FIP Display
Insert the Alignment Tape. (PAL: VFJ81215H3F) (NTSC: VFM8080HQFP) This adjustment is automatically started. (During the adjustment, the picture will be appeared on the monitor.) When this Adjustment is terminated, the following operation will be activated. -Adjustment completed: The tape will be ejected. -Adjustment incompleted: "F2*" is indicated on the FIP.Check the
Servo/System Control circuit and Cylinder Unit.
To release Service Mode, press the FF and EJECT keys. simultaneously 6 times until the normal indication on the FIP.
Fig. E1
4. ABBREVIATIONS
5. INPUT/OUTPUT CHART
5.1. INPUT/OUTPUT CHART FOR IC6001
Fig. MP1