It's great to be able to obtain a precious technical information for a real old equipment. The one I got helps me a lot in the area of wiring diagram to repair my antique. PDF gave me clear enough information to find out thr details. Thanks for giving me the oppotunity to be able to access to almost vanished informations.
 ;
Another excellent aquisition. Fine detailed manual. Thanks
5.1. New Error Code Display
Conventionally, the error code has been displayed automatically on the EVF or LCD Monitor when undesirable conditions have occurred. With the New Error Code Display, the error code has not been displayed automatically as follows except some error codesF31(Data Transmission Error), U10(Dew) and U11(Head Clogging).
Note:
1. The only some error codes F31, U10 and U11 has displayed automatically on the EVF or LCD monitor as usual. 2. The Power LED also has been flashed for 1 min. when undesirable condetions have occurred.(See below)
5.2. Viewing Error Code
When displaying the Error Code on the EVF or LCD Monitor, push the FADE/ STOP and REC START/PAUSE buttons simultaneously for more 3 seconds.
Note:
When the cassette tape is inserted, this operation will not be worked.