This PDF is very comprehensive. It includes drawings, parts lists, schematics, pictures, PCB drawings, mechanical layouts, etc. for all three stackable equipment. The scans are good too. Easy to read and no smudges or black lines. I have no complaints. I will make this site my first stop for finding my service manuals.
;
This service manual includes drawings, schematics, exploded views, parts list, operating details, and more. Very good scans, very readable. The only thing that made it a 4 star rating was on approximately 4 scans only half of the page was scanned then the other half. I would have preferred the pages to be whole scans.
;
Good manual contains all it takes to update, repair,these types of mixers.Thanks.
Troubleshooting flow chart 8:
The blank background is smeared.
Has the Image Drum been exposed to external light? No
Yes
Close and wait for about 30 minutes.
Is the heat roller of the fuser unit dirty? No
Yes
Clean it.
Is the contact of the cleaning roller Yes of the ID unit in contact with the contact assembly properly? No
Adjust the contact of the cleaning roller to contact the contact assembly properly.
Replace the EP unit or H10 Board MCNT (R76) Board
Troubleshooting flow chart 9:
Blank paper is output
Is the LED head connected properly? (Check connector CN4/CN5 on the MCNT (R76) Board.) Yes Is the ID unit set properly? Yes No
No
Connect to the LED print head properly.
Set the ID unit properly.
Replace the LED head,Power Supply Unit or MCNT (R76) Board.