Categories
|
Information
|
Featured Product
|
|
|
 |
|
There are currently no product reviews.
 ;
El producto satisface las necesidades del servicio t
 ;
This is a good quality scan of the Operation & Maintenance (Service) Manual for the PAL version of this high-band broadcast umatic, BVU-800P
All schematics and lineup procedures appear to be included in this one manual AFAICT.
The file size is just over 113 MB which gives an idea of the quality and number of pages.
All of the schematics, which contain some fairly small print, are easily readable when you zoom into the page.
John Thompson, Newcastle Upon Tyne, England.
 ;
Good quality, all schematics of few of models. There is also short form of user manual and regulation manual.
 ;
Perfect copy of the service manual. you can enlarge every page, and it comes up
with all details.
 ;
It´s very very nice manual with all, what i need. Original in good quality. Very fast business. Very much thanks...
Abgleich / Alignment
CUC 2103/M, 2121/M
Alignment 9. Line Sharpness
Preparations Colour video generator: Feed in a convergency test pattern. Contrast: maximum Set the screen brightness so that the black background of the test pattern just starts to brighten.
Alignment Process With focus control UF, adjust the vertical lines approx. 5cm from the right and left picture edge to minimum horizontal width. The sharpness in the middle must not seem to be worse than the sharpness at the edges. If necessary, take an average. Adjust according to the test pattern using button or .
10. Vertical position of the picture (Vertical Shift) 10.1 Vertical Amplitude 10.2 Vertical Linearity
Colour video generator: Feed in a geometry test pattern. Call up the "Vertical Shift" menu via " " (DIALOG CENTER) �> "OK" �> SERVICE �> "OK" �> Service Code "8500" �> "GEOMETRY" �> "OK". Call up the menu "Vertical Amplitude". Call up the menu "Vertical Linearit.".
Set the vertical amplitude using button
or
. or .
Adjust according to the test pattern using button
10.3 Horizontal position of the picture (Horizontal Shift)
Call up the menu "Horizontal Shift".
Adjust according to the test pattern using button
or
.
Go back to the "SERVICE" menu with " " and terminate the dialog line "End" "with mem" �> "OK".
2-4