Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Quick site processing. A complete and very useful manual with all details. Thank you!
 ;
Quick service response. A useful and very rare service manual with all details. I recomend this service.
 ;
I ordered this manual sometime in the afternoon and I received it on my e-mail the same evening.
This is a fantastically good and properly scanned copy of the original manual. All pages are of the same scale and they overlap each other. It means that you can print the manual and easily make it as a convenient paper manual.
The content of the manual is fantastic. Alignment descriptions, PCB layouts and elementary diagrams are explicit and precise. I immediately found what I was looking for. Thanks to this manual and Owner-Manuals.com my amplifier is alive again. Many thanx indded!
 ;
The manual was well-scanned and easy to read. As an added bonus, the Operator's Manual was bundled with the Service Manual!
I'd definitely use owner-manuals.com again.
 ;
Finally, i found one website, where i can download this service manual , and fix my hifi. The service manual is very good, and easy to download and to print.
TROUBLESHOOTING THE 50AF1 PANEL
(1)
YSUS
CN32
[YSUS - XSUS]
-Vs -Vs NC GND NC Vcc NC Vx NC GND NC Vs Vs
13 12 11 10 9 8 7 6 5 4 3 2 1
On Y-SUS board CN32 (1)-(4) pins or CN32 (6)-(4) pins or CN32 (8)-(10) pins or CN32 (10)-(13) pins shorted?
Y
Y-SUS board is defective.
Switching circuit (power supply) has a short-circuit.
N
Remove SDR from CN34 and CN35 on YSUS
A N A L Y S I S O P E R A T I O N
On CN801 on SDRU, or CN811 on SDRD, check for short circuit in following pins? (2)-(6), (20)-(24), (28)-(30), (46)-(50)
Y
SDR is defective.
N
On X-BUS board CN63 (1)-(9) shorted.
Y
XFPCs (Ribbon connectos to Panel)
Remove the six XFPCs (Disconnect CN61, CN62, CN63, CN64, CN65 and CN66)
N
On X-BUS board CN63 (1)-(9) are shorted.
N
Panel chassis is defective
Y
Remove XBUS-U XBUS-D
On X-BUS board CN63 (1)-(9) shorted?
Y
N
XBUS board is defective.
X-SUS board is defective.
(2)
End of analysis