Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Complete service and operation manual. All schematics are there, all circuit boards AND add-on boards. Including exploded views ,component names and specifications. Also electrical and mechanical adjustment procedures are in this manual. This manual also covers the more advanced BR-S811E unit. Scan quality is fair and usable.
 ;
High quality scan of original Service Manual. Everything´s fine!
 ;
Good scan of the original service manual. All schematics and adjustment procedures are there. It helped me to fix a long lasting problem with the tracking circuitry. The manual also includes the supplementals 1,2 and 3. Included are; electrical schematic's , pcb layout's, mechanical drawing's and exploded views, disassembly manual and maintenance procedures. 236 pages.
 ;
The Service Manual received was helpful. The electronic information is exactly what I needed.
I recomend all of my friends about this technical page.
 ;
High quality scan of service manual. I am satisfied!
PCD-001,PCD-002,PCD-003,PCD-004
1.2 SAFETY INFORMATION
IMPORTANT THIS PIONNER APPARATUS CONTAINS LASER OF CLASS 1. SERVICING OPERATION OF THE APPARATUS SHOULD BE DONE BY A SPECIALLY INSTRUCTED PERSON.
LASER DIODE CHARACTERISTICS MAXIMUM OUTPUT POWER : 5 mw WAVELENGTH : 780-785 nm
H. P. SOUND LABEL NYXTL type Only
LABEL CHECK
COMPLIES WITH FDA RADIATION PERFORMANCE STANDARDS,21 CER SUBCHAPTER J. MANUFACTURED ADT
FDA LABEL KUCXTL type Only
FCC/FDA/DOC LABEL KUCXTL type Only
WARNING LABEL NYXTL and NVXTL types
Bottom
BT CAUTION LABEL
Inside SW Laser P.U.
Additional Laser Caution SW102 (DOOR Detect SWITCH)
1. Laser Interlock Mechanism The position of the switch (SW102) for detecting the loading state is detected by the system microprocessor, and the design prevents laser diode oscillation except when both switch (SW102) is not on CLMP terminal side (CLMP signal is OFF or high level.). Thus, interlock will no longer function if switch (SW102) is deliberatery shorted (low level). The interlock also does not function in the test mode�. Laser diode oscillation will continue, if pin 36 of CXA1992A (IC102) on the CD AMP UNIT is connected to GND, or else the terminals of Q107 are shorted to each other(fault condition).
*
BATTERY
CD AMP UNIT
2. When the case is opened, close viewing of the objective lens with the naked eye will cause exposure to a Class 1 laser beam.
� Refer to page 19.
3
|
|
 |
> |
|