Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Very fast service, best quality of the service manual and the schematics
 ;
This service manual of the old video cassette recorder VT-LC50EM is very good readable even the tiniest numbers (i.e. IC-pins). The circuits are very clear. Many details of the schematic are very good described but in GERMAN language. Many schematic details - but complete at all. Common background information of several details are enclosed and physical knowledge of the TFT liquid crystal display for example. The manual lacks PCB drawings. If you understand german I would recommend this manual for you.
 ;
Hi, this is a very clear manual, nice copy, not quite up to the standard of the very best available but better than many others. I think the price was especially fair for a hard to find manual and I would certainly use this manual seller again. Recommended.
 ;
This schema available for me in good condition. I would highly recommend.
 ;
Thanks for this "hard to find" service manual.
I apreciate the good quality of scanning and the pages scanned in A3 format.
PCD-001,PCD-002,PCD-003,PCD-004
1.2 SAFETY INFORMATION
IMPORTANT THIS PIONNER APPARATUS CONTAINS LASER OF CLASS 1. SERVICING OPERATION OF THE APPARATUS SHOULD BE DONE BY A SPECIALLY INSTRUCTED PERSON.
LASER DIODE CHARACTERISTICS MAXIMUM OUTPUT POWER : 5 mw WAVELENGTH : 780-785 nm
H. P. SOUND LABEL NYXTL type Only
LABEL CHECK
COMPLIES WITH FDA RADIATION PERFORMANCE STANDARDS,21 CER SUBCHAPTER J. MANUFACTURED ADT
FDA LABEL KUCXTL type Only
FCC/FDA/DOC LABEL KUCXTL type Only
WARNING LABEL NYXTL and NVXTL types
Bottom
BT CAUTION LABEL
Inside SW Laser P.U.
Additional Laser Caution SW102 (DOOR Detect SWITCH)
1. Laser Interlock Mechanism The position of the switch (SW102) for detecting the loading state is detected by the system microprocessor, and the design prevents laser diode oscillation except when both switch (SW102) is not on CLMP terminal side (CLMP signal is OFF or high level.). Thus, interlock will no longer function if switch (SW102) is deliberatery shorted (low level). The interlock also does not function in the test mode�. Laser diode oscillation will continue, if pin 36 of CXA1992A (IC102) on the CD AMP UNIT is connected to GND, or else the terminals of Q107 are shorted to each other(fault condition).
*
BATTERY
CD AMP UNIT
2. When the case is opened, close viewing of the objective lens with the naked eye will cause exposure to a Class 1 laser beam.
� Refer to page 19.