Who's Online
There currently are 6028 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
the manual is in good quality and it's in pdf. manual was send in less then 24h.
regards
mike
;
I would not plug this machine in without finding a manual like this. In addition to setup and normal operating instructions, it has troubleshooting flowcharts, diagrammed mechanical adjustments, and schematics to beat the band. The tech I hand it to would be thrilled to find solder side PCB diagrams with component outlines superimposed, pinouts for every IC chip, and line drawings of transistors, with labeled legs.
As for printing quality, this may be a copy of a copy, but even the finest print when enlarged is very legible. There is a bit of grayed print over a few pages, as if a wet page were placed over it, but the print is still very legible. If you could borrow an original manual and get it printed and bound for 4 to 6 times the cost, you could get better quality. In that case you wouldn't be here. For price, utility, and availability I am rating this manual highly.
;
I received the Manual in a timely manner and it was exactly what I needed.
This is a perfect copy of the Service Manual, The quality is great. I am very
happy. Thank you
;
exactly as they say. Within 24 hours the link to the pages and offcourse it was the right service manual. Super and thanks
;
The manual was exact the thing that was promised. My old car stereo is working again thanks to the information supplied.
4-1. Check Items Before Starting Self-diagnostics
3. When the DE-55 board is suspected to be defective . Select an oscilloscope setup of 20 MHz with band-width limit: OFF. . Adjust the brightness of the incoming light until 400 mVp-p is obtained at TP401 and TP402. . The circuit stage up to TP141 must be diagnosed by observing the waveform of the carrier signal and by checking the operating condition with no input signal fed to the infrared transmitter. The circuit stages after that must be diagnosed by observing the demodulated waveform and by checking the operating condition with the color bar signal being input to the infrared transmitter. a) Check that the DC voltages that are supplied from the power supply to the respective blocks are correct or not. � When the DC voltages are normal, the voltages from MA-107/107P board are; TP491: 5 ± 0.5 V, TP391: 9 ± 0.5 V. � When DC voltages are abnormal; Soldering of CN101 is suspected to be defective, or flexible flat cable (FFC) has poor connection or is broken. b) Check DC voltage at L491 and check the signal flow from TP401 to TP404. [RF amplifier] � When the circuit is normal, the waveforms [No. 1 to No. 5] that are shown on page 4-21 can be obtained with no input signal fed to the infrared transmitter. � When the circuit is found abnormal; Resoldering the poorly soldered joint in the circuit block of Ref. 400 to Ref. 409. Replace the transistor as needed. c) Check DC voltage at L492 and check the signal flow from TP421 to TP424. [RF amplifier] � When the circuit is normal, the waveforms [No. 1 to No. 5] that are shown on page 4-21 can be obtained with no input signal fed to the infrared transmitter. � When the circuit is found abnormal; in the circuit block of Ref. 420 to Ref. 439. Replace the transistor as needed. d) Check DC voltage at L491. [ANALOG_5.9 V] � When the circuit is normal; 5.9 ± 0.5 V � When the circuit is found abnormal; Resoldering the poorly soldered joint in the circuit block in which abnormality has occurred. Replace the transistor Q901 or others as needed. e) Check Q110 for correct operation by observing the output waveform at TP101. [BUFFER] � When the circuit is normal, the waveform [No. 6] that is shown on page 4-21 can be obtained with no input signal fed to the infrared transmitter. � When the circuit is found abnormal; Resoldering the poorly soldered joint in the circuit block in which abnormality has occurred. Replace the transistor Q110 or others as needed. f) Check IC101 for correct operation by observing the output waveform at TP102. [LIMITTER] � When the circuit is normal, the waveform [No. 7] that is shown on page 4-22 can be obtained with no input signal fed to the infrared transmitter. � When the circuit is found abnormal; Resoldering the poorly soldered joint in the circuit block in which abnormality has occurred. Replace IC101 or others as needed.
4-18
PCS-1600/1600P
|
|
|
> |
|