|
|
|
Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Fully functional usable service manual. Considering the age of the manual and device quality was better than expected
 ;
Thank you very much, I've been very happy to find this manual on "Owner Manual". It's a perfect copy and it has been really useful for my work!
 ;
It took about 24-hours after my payment before I was able to get to the download. Apparently, payment processing is not 100% automated. That is no big deal, just be aware of that going in.
After I got to it, it was in good shape, easy to read, etc. Not some cheap FAX copy looking thing.
Also, this site was the cheapest I found. Another Plus!
 ;
Good price, very legible manual, exactly what I needed -- but had to wait a day to actually get the download of the manual. Would have preferred to download it immediately after payment rather than waiting for someone to "process" my order. I was surprised that I had to wait that long.
 ;
As the only source for this manual it rather rank quite high since it is well scanned and perfectly readable.
PC-XC350
Electrical Performance
Items Measurement conditions Adjustment of recording blas current (Reference Value) Mode: Playback mode Recording mode Test tape TDK-D60 Measurement output terminal : Both recording and headphone terminals Reference frequency :1KHz and 8KHz (REF.:-10dB) Test tape TDK-D60 Measurement input terminal : OSC IN 1 With the recording and playback mechanism, load the test tapes TDK-D60, and set the mechanism to the recording and pausing condition in advance. 2 After connecting 100 in series to the recorder head, measure the blas current with a valve voltmeter at both of the terminals 1 with the recording and playback mechanism, load the test tapes (TDK-D60) and set the mechanism to the recording and pausing condition in advance 2 While repetitively inputting the reference frequency signal of 1KHz and 8KHz from OSC IN, record andplayback the tape. 3 While recording and playback the test tape Lch and Rch so that the output deviation between 1KHz and 8KHz from -1dB +/-2dB Output deviation between 1KHz and 8KHz :-1dB +/-2dB Measurement method Standard Values TDK-D60 4.5 u A +/-0.5u A Adjusting position
Adjustment of recording and palyback frequency characteristics
Reference Values for Electrical Function Confirmation Items
Items Measurement conditions Recording blas frequency Playback Test tape TDK-D60 Measurement terminal : BIAS TP on P.C. board 1 While changing over t and form BIAS 1 and 2, confirm that the frequency is changed. 2 With the recording and playback mechanism, load the test tape. (TDK-D60), and set the mechanism to the recording and pausing condition in advance. 3 Confirm that the BIAS TP frequency on the P.C. board is 64KHz +/-6KHz Measurement method Standard Values 64KHz +/-6KHz T201 Adjusting position
1-10
|
|
 |
> |
|