thank u so much for this manual that was so cheap that i thought it was a scam but i gambled anyway because it was too good of a deal to pass up and behold,the manual has everything and details of everything even the screws and im still amazed and very happy with my manual .so take my word and jump on it before they realize how cheap they selling thier manuals..thank you so much for taking time to read my thoughts
PC-XC350
Electrical Performance
Items Measurement conditions Adjustment of recording blas current (Reference Value) Mode: Playback mode Recording mode Test tape TDK-D60 Measurement output terminal : Both recording and headphone terminals Reference frequency :1KHz and 8KHz (REF.:-10dB) Test tape TDK-D60 Measurement input terminal : OSC IN 1 With the recording and playback mechanism, load the test tapes TDK-D60, and set the mechanism to the recording and pausing condition in advance. 2 After connecting 100 in series to the recorder head, measure the blas current with a valve voltmeter at both of the terminals 1 with the recording and playback mechanism, load the test tapes (TDK-D60) and set the mechanism to the recording and pausing condition in advance 2 While repetitively inputting the reference frequency signal of 1KHz and 8KHz from OSC IN, record andplayback the tape. 3 While recording and playback the test tape Lch and Rch so that the output deviation between 1KHz and 8KHz from -1dB +/-2dB Output deviation between 1KHz and 8KHz :-1dB +/-2dB Measurement method Standard Values TDK-D60 4.5 u A +/-0.5u A Adjusting position
Adjustment of recording and palyback frequency characteristics
Reference Values for Electrical Function Confirmation Items
Items Measurement conditions Recording blas frequency Playback Test tape TDK-D60 Measurement terminal : BIAS TP on P.C. board 1 While changing over t and form BIAS 1 and 2, confirm that the frequency is changed. 2 With the recording and playback mechanism, load the test tape. (TDK-D60), and set the mechanism to the recording and pausing condition in advance. 3 Confirm that the BIAS TP frequency on the P.C. board is 64KHz +/-6KHz Measurement method Standard Values 64KHz +/-6KHz T201 Adjusting position