Received via e-mail this PDF manual is worth the money. This is a quality scan of a manual in excellent condition and is just as good as having the original manual in hand. I have later seen the original manual and it was printed in colour, but this particular manual is black & white but scan resolution is high end quality! All drawings and pictures are presented in great detail. So, nearly perfect score in my opinion.
If you own the turntable you also should own the manual!
 ;
I was very satisfied with the service manual I ordered and downloaded. I will definitely buy again from this seller.
 ;
Great product. Recieved it fast...exactly as advertised.
Panel W/B
Composite/Component signal Equipment NTSC (or PAL according to the system) signal generator Color meter
1) Set the AV mode and input the white pattern signal from NTSC (or PAL according to the system) signal generator. 2) Press the Menu button twice to access main menu and set the manual W/B to Cool. 3) Access the Panel W/B mode and align the Low Light and High Light shown below by using color meter.
x
Cool (High) Normal (Mid) Warm (Low) 0.272 0.288 0.313
y
0.290 0.296 0.329
Alignment Item
Brightness R Cutoff B Cutoff B Drive R Drive Contrast 4)
Reference Cool (Hi)
71 7F 7D 75 62 84
Setting/Special feature
10cd/m2 by 15% signal level (Set by generator) Set to 15% signal level by the generator. Set 15% signal level by the generator. Set 75% signal level by the generator. Set 75% signal level by the generator. Optimum setting
Record R Cutoff, B Cutoff, R Drive and B Drive setting data.(***Data 3)
***Data 3
Manual W/B
Cool (High) Normal (Mid) Warm (Low) 5) 6)
R Cutoff
B Cutoff
B Drive
R Drive
Change the Manual W/B to Normal by the Menu button and STR button. Modify the Data as follows. Increase R Drive 24 steps and reduce B drive 2 steps and B cutoff 1 step from Cool mode. 7) Change the Manual W/B to Warm by the Menu button and STR button. 8) Modify the Data as follows. Increase R Drive 30 steps and reduce B drive 35 steps, and B cutoff 2 steps from Cool mode. 9) Access the SG Hold mode (Forced signal system set mode) and set the system to NTSC (or PAL). 10) Return to the Panel W/B mode and copy the Data 3 for each item. 11) Repeat item 9) and 10) for SECAM system.