|
|
|
Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
8-17-12 Been using the sight for about 6 months. Fast Downloads and top quality
Manuels !
 ;
Everything was great, the manual, the response time, the simplicity of the order, and the
Price. The only thing that I could possible say on a negative note would be that the manual I ordered was more for a service tech. There were a lot of schematic diagrams that didn't help me solve the problem. However I would order again and recommend the web sight to others.
 ;
I'd been looking for this manual for awhile. Exactly what I needed - and at an excellant price. Thanks!
 ;
very complete. acceptable resolution. details are a little unclear. is a manual note 8.
 ;
excellent service - fast purchase - easy download - will buy from again
PD-F607, PD-F507
1. SAFETY INFORMATION
This service manual is intended for qualified service technicians; it is not meant for the casual do-it-yourselfer. Qualified technicians have the necessary test equipment and tools, and have been trained to properly and safely repair complex products such as those covered by this manual. Improperly performed repairs can adversely affect the safety and reliability of the product and may void the warranty. If you are not qualified to perform the repair of this product properly and safely, you should not risk trying to do so and refer the repair to a qualified service technician.
IMPORTANT THIS PIONNER APPARATUS CONTAINS LASER OF CLASS 1. SERVICING OPERATION OF THE APPARATUS SHOULD BE DONE BY A SPECIALLY INSTRUCTED PERSON.
LASER DIODE CHARACTERISTICS MAXIMUM OUTPUT POWER : 5 mw WAVELENGTH : 780-785 nm
LABEL CHECK (For PD-F607/WYXJ,WVXJ and PD-F507/WPWXJ only)
PD-F607/WYXJ only
Additional Laser Caution
1. Laser Interlock Mechanism The position of the switch (S651) for detecting loading state is detected by the system microprocessor, and the design prevents laser diode oscillation when the switch (S651) is not on CLMP terminal side (CLMP signal is OFF or high level). Thus, the interlock will no longer function if the switch (S651) is deliberatery set to CLMP terminal side. (low level) The interlock also does not function in the test mode V. Laser diode oscillation will continue, if pin 33 of CXA1782CQ (IC151) on the MOTHER BOARD ASSY is connected to GND, or pin 26 of IC351 (LDON) is connected to low level (ON), or else the terminals of Q151 are shorted to each other (fault condition). 2. When the cover is opened, close viewing of the objective lens with the naked eye will cause exposure to a Class 1 laser beam. V : Refer to page 25. on the service manual RRV1877.
AR RE
PD-F607/WVXJ and PD-F507/WPWXJ only
2
|
|
 |
> |
|