The service manual when downloaded and printed out was clear and easy to read. I would have liked to have been able to enlarge some details, but this was not possible as the file permissions did not allow this. The service was very good. The time taken from placing my order to downloading the document was only a few minutes.
 ;
The manual is useful for trouble shooting for an old instrument. It saved money,and let me enjoy DIY.
 ;
Perfect source of information for replacing the HDD and performing general diagnostics.
 ;
Perfect source of information for replacing the HDD and performing general diagnostics.
 ;
Very good scanned copies. Quick response and reasonable price. Thanks for service!
1
2
3
4
A
4) No Power
Check the condition of the input power & cable connection. (JP35(3V3STB, A+12V, +6.5V), JP36(5VSTB,35V), JP34(5V), JP33(S_16.5V)) Check the condition of on-board regulators. Check for short circuits between each power terminal and the ground.
B
No Power When Powered On
#5,6,7(3V3STB) at JP35 in Main Assy
NG
Check Power supply unit & the short circuit between 3V3STB and GND
#3(5VSTB) at JP36 In Main Assy Waveform 1 #9,11(M_SDA/SCL) at J1(When power on) In Main Assy
NG
Check Power supply unit & the short circuit between 5VSTB and GND
NG
Check Power supply unit & Panel Module
C
Check 1V8VDD 2V5VDDLine at U47,48 In Main Assy Waveform 2 The signal waveform of Y1 in Main Assy NG Check the power of +3V3_PLL and replace the part of Y3 NG Check the state of soldering in U47, U48 and related components.
D
Check the other Power of Power supply unit (A+12V,+6.5V,5V,+16.5V)
NG
Check for short circuits between each power terminal and the ground
Change Main Assy
� Waveform
E
<Waveform 1>
<Waveform 2>
F
T01
132
1 2
T01
PDP-5016HD