A
Recovery flowchart (1-1)...Changing the Vol Offset setting voltage
Note: Disregard the discharge that may appear during voltage-change setting.
[From the main flowchart (1)]
Display RST MASK 09 (light blue). / [MKS S59]
� If RST MASK 09 (light blue) is already displayed, skip this step.
B
Set VOL OFFSET to the setting value 000. / [VOF 000] � This setting becomes VOL OFFSET_min1.
Gradually increase the VOL OFFSET value until disappear the discharge (lit cell). The VOL OFFSET value must be 245 or less.
VOL OFFSET_min1
Note: Make a note of this VOL OFFSET_min1 value.
VOL OFFSET_min1
C
155?
No
Replacement of abnormal circuits or re-replacement of the panel required
Yes Display RST MASK 10 (light purple). / [MKS S60]
Set VOL OFFSET to the setting value 000. / [VOF 000] � This setting becomes VOL OFFSET_min2.
Gradually increase the VOL OFFSET value until disappear the discharge (lit cell). The VOL OFFSET value must be 245 or less.
D
VOL OFFSET_min2
Note: Make a note of this VOL OFFSET_min2 value.
VOL OFFSET_min2
155?
No
Replacement of abnormal circuits or re-replacement of the panel required VOL OFFSET_min
Yes Choose the higher value between VOL_OFFSET_min1 and VOL_OFFSET_min2, and set it as VOL_OFFSET_min.
[To the Recovery flowchart (1-2)]