Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
The service manual was a copy of the original from Wirlpool. The quality was good, all neccecary information was available including the service-codenumbers, so I could order the right part to be replaced for repair.
Downloding was no probem after the payment.
Thanks for the service!
 ;
Good,readable manual. I found other manuals that were not readable when it came to part ID, but the one downloaded from owner-manual.com was better than expected. I will do buisness with owner-manual.com again.
 ;
Service Manual that I received was very helpful to me. Thank you.
 ;
The manual is well organized and is easy to read. The chapters are following normal way to proceed.
 ;
This scanned manual is well done in that most all the pages except for one is straight and clear- the way I would do them. One page was upside down but that happens. For the money that is charged on this site you get a pretty good deal. Now with complex repairs, I still prefer to us paper manuals which I have to buy at stereomanuals but the one I got here was much less than the $45 he was charging but this is a larger than normal manual for three different units. I am a picky manual user because I have used original manuals from Sony and Teac.
1
2
3
4
A
Recovery flowchart (1-1)...Changing the Vol Offset setting voltage
Note: Disregard the discharge that may appear during voltage-change setting.
[From the main flowchart (1)]
Display RST MASK 09 (light blue). / [MKS S59]
� If RST MASK 09 (light blue) is already displayed, skip this step.
B
Set VOL OFFSET to the setting value 000. / [VOF 000] � This setting becomes VOL OFFSET_min1.
Gradually increase the VOL OFFSET value until disappear the discharge (lit cell). The VOL OFFSET value must be 245 or less.
VOL OFFSET_min1
Note: Make a note of this VOL OFFSET_min1 value.
VOL OFFSET_min1
C
155?
No
Replacement of abnormal circuits or re-replacement of the panel required
Yes Display RST MASK 10 (light purple). / [MKS S60]
Set VOL OFFSET to the setting value 000. / [VOF 000] � This setting becomes VOL OFFSET_min2.
Gradually increase the VOL OFFSET value until disappear the discharge (lit cell). The VOL OFFSET value must be 245 or less.
D
VOL OFFSET_min2
Note: Make a note of this VOL OFFSET_min2 value.
VOL OFFSET_min2
155?
No
Replacement of abnormal circuits or re-replacement of the panel required VOL OFFSET_min
Yes Choose the higher value between VOL_OFFSET_min1 and VOL_OFFSET_min2, and set it as VOL_OFFSET_min.
[To the Recovery flowchart (1-2)]
E
F
130
1 2
PDP-4280HD
3 4
|
|
 |
> |
|