8.6 PRECAUTION ON REPLACEMENT OF THE POWER SUPPLY UNIT
A
Attachment of the housing wire
The housing wire (J126) is attached to the P11 terminal of the POWER SUPPLY unit. As the housing wire is not provided with the POWER SUPPLY unit for service, when replacing the POWER SUPPLY unit, remove the housing wire (J126) from the old one and attach it to the new one. NEVER turn on the unit before replacement, as doing so may damage the PC boards or the product. Note: The wiring shown in the photo is different from the actual power supply unit, because the product in the photo is a prototype.
B
POWER SUPPLY unit
C
D
1
Disconnect the housing wire (J126) from the P11 terminal on the old POWER SUPPLY Unit. Housing wire (J126)
2
Connect the housing wire (J126) to the P11 terminal on the new POWER SUPPLY Unit. Housing wire (J126)
E
1
P11
2
P11
F
POWER SUPPLY unit (old)
POWER SUPPLY unit (new)