Who's Online
There currently are 5711 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
The Service Manual for Sansui AU-9500 was very helpfull, in complete and in good printable condition.
Thanks.
;
Dear Sir,
Document is original service document of sharp. I had a problem with the door contacts. Fuses where blown. With the manual in a few minuts is was clear what the problem was.
Manual was of great help.
With kind regards,
Martie Verhoeven
The Netherlands.
;
The scan is clear and well readable with very few weaker spots, usually on black background with white letters, but with enough zoom those spots can be read.
Printout is clear, the manual is complete and has all pages scanned.
I would give 5 stars, except that it is not in color, and the schematic and PCB pages are scanned on multiple pages. The document is locked (except printing) so the pages can not be extracted to compose them together for printing on the large plotter
It is worth the price tag.
;
let's say first that i do not need to have a credit for my opinion, i am a retired sparkie and i voluteerd to fix an electronic device for a local "Youthgroup",as no diagram was present i checked the "net" and gambled on this site and paying some fee via PayPall, i was gladly surprised that the manual arrived as was stated, GOOD SHOW, and best wishes, John
;
I had been looking for a Manual for my CS2150 for quite a while -- in fact I had just about given up. I saw this site and decided to download the Manual. When I Received it by Email I was really pleased with what I got, with the result that My Kenwood 'Scope is now 100% repaired and working well. As an AV Serviceman, you need a good 'scope, and thanks to this site, and the Service Manual, I have been able to repair it. The Manual was a copy of the Factory Original and the copy was very clear, especially in the area of the Circuit Schematics, where You really need to be sure of what You are looking at.
5
6
7
8
6.3 METHOD FOR REPLACING THE SERVICE PANEL ASSY
A
When the Panel Assy is replaced with one for service, the following adjustments are required:
Adjustments of Vofs voltage and Vyprst voltage
Enter the reference adjustment values for the Vofs voltage and Vyprst voltage that are written on the label attached to the panel for service. Note: Enter the values, using an RS-232C command or the Factory Menu.
AWU���� Vofs = 35V Vyprst = 270V Hour Meter Space H (Rear of the Panel) AWU���� Vofs = 35V Vyprst = 270V Hour Meter 1520 H Write in the value for the hour meter when the Panel is replaced (ex. 1520H).
B
Using an RS-232C command Enter a "PFY" command with Factory mode ON. Convert the adjustment voltage values written on the label attached at the rear of the Panel to an input command, referring to the conversion chart. (See the next page.) � Reference adjustment of the Vofs voltage: Ex. "Vofs = 35" � (Check the conversion chart.) Enter "VOF112." � Reference adjustment of the Vyprst voltage: Ex. 50-inch "Vyprst = 270 V" � (Check the conversion chart.) Enter "VRP055." (Note that the conversion charts for 50-inch and 43-inch Panels are different.) Using the Factory Menu
1 1 5 10 15 20 25 30 32 1 1 5 10 15 20 25 30 32
P AN E L
FAC T .
VD 1 � 1 1 6 01 � NT V � J HS 6 [ TBL 1 / 6 0 VS ]
P AN E L
FAC T . ADJ
VD 1 � 1 1 6 01 � NT V � J HS 6 [ TBL 1 / 6 0 VS ]
P AN E L � 1
5
C
5
10
10
15 16
P AN E L � 1
ADJ
(+)
15 16
VOL
RST
P
<=>
: 058
Select the main item "PANEL FACT." by pressing the MUTE key then enter Panel Factory mode by pressing the SET key. Using the 5/� keys, select "PANEL-1 ADJ" then press the SET key to enter the next lower nested layer. Select "VOL-OFFSET" or "VOL RST P" then enter a command value converted from the voltage value, using the 2/3 keys.
D
Clearing data on various histories of the Panel, such as those on the hour meter
� It is necessary to clear the data on the hour meter, etc. to match them to the actual driving hours of the Panel. � It is also necessary to clear the data on SD and PD, because the accumulated power-on time when a shutdown or powerdown occurred is recorded. Note: Clear the values, using an RS-232C command or the Factory Menu. There are two types of hour meters. Do not take the MR hour meter for the hour meter. Using an RS-232C command To acquire the accumulated power-on time of the product itself, use the "GS2" RS-232C command. 1 To clear the data on the hour meter (for the Panel) : CHM 2 To clear the data on the pulse meter : CPM 3 To clear the data on the SD history : CSD 4 To clear the data on the PD history : CPD
E
Using the Factory Menu See "7.1.7 HOW TO CLEAR HISTORY DATA."