Shopping cart is empty
 
English Polski Spanish 
Search For a Manual
 

(e.g. AA-V20EG JVC, ZX-7 Sony )
PayPal 1000+ rating Secure, Encrypted Checkout.
 
Categories
Information
Featured Product
Home >> PIONEER >> PDP-436SXE Service Manual
 
 0 item(s) in your cart 

PIONEER PDP-436SXE
Service Manual


Tweet about this product and get $1.00 of store credit for instant use!
  • Contains Circuit Diagrams
  • Download
  • PDF Format
  • Complete manual
  • Language: English
Price: $4.99

Description of PIONEER PDP-436SXE Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagrams, printed circuit boards, repair tips, wiring diagrams, block diagrams and parts list. Service Manual ( sometimes called Repair Manual ) is used mainly by technicians.

If You just want to know how to use Your tv, video, mp3 player etc. You should look for Owner's Manual. After placing order we'll send You download instructions on Your email address.

The manual is available in languages: English

Not yet ready
You must purchase it first

Customer Reviews
There are currently no product reviews.
Other Reviews
 2100 MARANTZ Service Manual by Niels Van den Borre;
Very good scanning quality. All schematics are very legible. Worth every cent !
 TC8802 SONY Service Manual by Andrew Hearn;
Excellent quality, very quick download turnaround, will definately use again.
 SU8099/K TECHNICS Service Manual by Mike Ischuk;
This is a awesome quality scan of the original Service Manual for Technics 8099. Contains the circuit diagram, PCB layout, adjust/tune instructions as well. Since this is my first buy here, i'm really glad! This site do works as intended/described, it's definitely not scam! Мои рекомендации! Все мануалы настоящие!
 CCU-M5P SONY Service Manual by Johannes Zündel;
Good Quality of the File. You get the normal manual is incudet.
 22DC795 PHILIPS Service Manual by Светослав Георгиев;
Very nice and real Service Manual, I didn't thought it actually exist in the real world at all.

Text excerpt from page 100 (click to view)
1

2

3

4

6.6 METHOD FOR REPLACING THE SERVICE PANEL ASSY
A

When the Panel Assy is replaced with one for service, the following adjustments are required:

Adjustments of Vofs voltage and Vyprst voltage
Enter the reference adjustment values for the Vofs voltage and Vyprst voltage that are written on the label attached to the panel for service. Note: Enter the values, using an RS-232C command or the Factory Menu.
AWU���� Vofs = 35V Vyprst = 270V Hour Meter Space H (Rear of the Panel)
B

AWU���� Vofs = 35V Vyprst = 270V Hour Meter 1520 H Write in the value for the hour meter when the Panel is replaced (ex. 1520H).

Using an RS-232C command Enter a "PFY" command with Factory mode ON. Convert the adjustment voltage values written on the label attached at the rear of the Panel to an input command, referring to the conversion chart. (See the next page.) � Reference adjustment of the Vofs voltage: Ex. "Vofs = 35" � (Check the conversion chart.) Enter "VOF112." � Reference adjustment of the Vyprst voltage: Ex. 50-inch "Vyprst = 270 V" � (Check the conversion chart.) Enter "VRP055." (Note that the conversion charts for 50-inch and 43-inch Panels are different.) Using the Factory Menu
1 1 5 10 15 20 25 30 32 1 1 5 10 15 20 25 30 32

P AN E L

FAC T .

VD 1 � 1 1 6 01 � NT V � J HS 6 [ TBL 1 / 6 0 VS ]

P AN E L

FAC T . ADJ

VD 1 � 1 1 6 01 � NT V � J HS 6 [ TBL 1 / 6 0 VS ]

C
5

P AN E L � 1
5

10

10

15 16

P AN E L � 1

ADJ

(+)

15 16

VOL

RST

P

<=>

: 058

D

Select the main item "PANEL FACT." by pressing the MUTE key then enter Panel Factory mode by pressing the SET key. Using the 5/� keys, select "PANEL-1 ADJ" then press the SET key to enter the next lower nested layer. Select "VOL-OFFSET" or "VOL RST P" then enter a command value converted from the voltage value, using the 2/3 keys.

Clearing data on various histories of the Panel, such as those on the hour meter
� It is necessary to clear the data on the hour meter, etc. to match them to the actual driving hours of the Panel. � It is also necessary to clear the data on SD and PD, because the accumulated power-on time when a shutdown or powerdown occurred is recorded. Note: Clear the values, using an RS-232C command or the Factory Menu. There are two types of hour meters. Do not take the MR hour meter for the hour meter.
E

Using an RS-232C command To acquire the accumulated power-on time of the product itself, use the "GS2" RS-232C command. 1 To clear the data on the hour meter (for the Panel) : CHM 2 To clear the data on the pulse meter : CPM 3 To clear the data on the SD history : CSD 4 To clear the data on the PD history : CPD

Using the Factory Menu See "7.1.6 HOW TO CLEAR HISTORY DATA."