Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
I was having a hard time finding the problem with this Mackie 1604 unit. I didn't have a schematic. Went looking on the web and found your site and the price was more then reasonable. Ordered it and within the hour had the manual and within 15 minutes had the unit fixed. Best $4.99 I ever spent. Thank you.
Doug
 ;
This is a service manual in every sense of the word ( French and German versions of the text are included, as well as English..)
There are explanations of the mechanical and electrical functions, plenty of mechanical drawings, and the needed schematics. The quality of the scanning is excellent - all the component values are clearly legible - and very usefully there are pcb component layouts, so you can find a component on the schematic, and then very quicky pinpoint its physical location on the relevant pcb.
I cannot see how I can give this manual any less than the maximum 5 stars! Great value for money, which will pay for itself immediately. Excellent all round!
 ;
the manual is great and especially hard to find... thanks for the great service and having a hard to find manuel_
 ;
Please tell us what you think and share your opinions with others. Be sure to focus your comments on the product. You will receive $2.50 of store credit for Your review.
 ;
hat alles sehr gut geklappt. Das Servicemaual ist gut zu verwenden. Die Pläne und Schrift
ist klar und leserlich. Außerdem preiswert. Grüße an alle Hifi-Bastler
PDP-502MX, PDP-502MXE
Procedure
Adjusting Item
Base Pulse
Input signal
Any input
Adjusting Point
SUB VIDEO mode in Factory mode PULSE NUMBER ........."8" Key
Adjusting Method
Set to the indicated value with the keys on the remote control unit. (refer to SUB VIDEO mode)
11
number Adjustment (502MX only)
Note) If unnecessarily adjusted, power consumption is changed and the panel is damaged. Adjust only in case of necessity. SUB VIDEO mode Set to the indicated value with the keys on the remote control unit.
12
ABL Level Value Adjustment (502MX only)
Any input
in Factory mode (refer to SUB VIDEO mode) ABL LEVEL ...."9" Key
Note) If unnecessarily adjusted, power consumption is changed and the panel is damaged. Adjust only in case of necessity. REFERENCE 1 in Factory mode ABL LEV OFFSET ........."BS9" Key Adjust to the ABL value mentioned on the "Drive voltage label" at the chassis of the glass panel.
Any input
13
ABL Level Offset adjustment
Note) If unnecessarily adjusted, power consumption is changed and the panel is damaged. Adjust only in case of necessity. REFERENCE 1 in Factory mode PLS NUM OFFSET ........."BS11" Key Note) If unnecessarily adjusted, power consumption is changed and the panel is damaged. Adjust only in case of necessity. Set to the indicated value with the keys on the remote control unit. (refer to REFERENCE 1 mode)
Any input
14
Pulse Number Offset adjustment
Adjusting points and Measuring points 54
|
|
 |
> |
|