|
|
|
Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
This is a good quality scan of the Operation & Maintenance (Service) Manual for the PAL version of this high-band broadcast umatic, BVU-800P
All schematics and lineup procedures appear to be included in this one manual AFAICT.
The file size is just over 113 MB which gives an idea of the quality and number of pages.
All of the schematics, which contain some fairly small print, are easily readable when you zoom into the page.
John Thompson, Newcastle Upon Tyne, England.
 ;
Good quality, all schematics of few of models. There is also short form of user manual and regulation manual.
 ;
Perfect copy of the service manual. you can enlarge every page, and it comes up
with all details.
 ;
It´s very very nice manual with all, what i need. Original in good quality. Very fast business. Very much thanks...
 ;
Purchased the manual that I was looking for at a great price and could download it easily.. Great service experience and for future purchases I plan to use the site.
Thank you very much
PDP-502MX, PDP-502MXE
Procedure
Adjusting Item
Base Pulse
Input signal
Any input
Adjusting Point
SUB VIDEO mode in Factory mode PULSE NUMBER ........."8" Key
Adjusting Method
Set to the indicated value with the keys on the remote control unit. (refer to SUB VIDEO mode)
11
number Adjustment (502MX only)
Note) If unnecessarily adjusted, power consumption is changed and the panel is damaged. Adjust only in case of necessity. SUB VIDEO mode Set to the indicated value with the keys on the remote control unit.
12
ABL Level Value Adjustment (502MX only)
Any input
in Factory mode (refer to SUB VIDEO mode) ABL LEVEL ...."9" Key
Note) If unnecessarily adjusted, power consumption is changed and the panel is damaged. Adjust only in case of necessity. REFERENCE 1 in Factory mode ABL LEV OFFSET ........."BS9" Key Adjust to the ABL value mentioned on the "Drive voltage label" at the chassis of the glass panel.
Any input
13
ABL Level Offset adjustment
Note) If unnecessarily adjusted, power consumption is changed and the panel is damaged. Adjust only in case of necessity. REFERENCE 1 in Factory mode PLS NUM OFFSET ........."BS11" Key Note) If unnecessarily adjusted, power consumption is changed and the panel is damaged. Adjust only in case of necessity. Set to the indicated value with the keys on the remote control unit. (refer to REFERENCE 1 mode)
Any input
14
Pulse Number Offset adjustment
Adjusting points and Measuring points 54
|
|
 |
> |
|