Procedure
Adjusting Item
Input signal
Any input
Adjusting Point
SUB VIDEO mode in Factory mode PULSE NUMBER ........."8" Key
Adjusting Method
Set to the indicated value with the keys on the remote control unit. (refer to SUB VIDEO mode)
Base Pulse
11
number Adjustment
Note) If unnecessarily adjusted, power consumption is changed and the panel is damaged. Adjust only in case of necessity. SUB VIDEO mode Set to the indicated value with the keys on the remote control unit.
12
ABL Level Value Adjustment
Any input
in Factory mode (refer to SUB VIDEO mode) ABL LEVEL ...."9" Key
Note) If unnecessarily adjusted, power consumption is changed and the panel is damaged. Adjust only in case of necessity. REFERENCE 1 in Factory mode ABL LEV OFFSET ........."BS9" Key Adjust to the ABL value mentioned on the "Drive voltage label" at the chassis of the glass panel.
Any input
13
ABL Level Offset adjustment
Note) If unnecessarily adjusted, power consumption is changed and the panel is damaged. Adjust only in case of necessity. REFERENCE 1 in Factory mode PLS NUM OFFSET ........."BS11" Key Note) If unnecessarily adjusted, power consumption is changed and the panel is damaged. Adjust only in case of necessity. Set to the indicated value with the keys on the remote control unit. (refer to REFERENCE 1 mode)
Any input
14
Pulse Number Offset adjustment