Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
A site where discontinualed schematic diagrams and back dated information can be found on discontinued radios tv's and any electronic equipment can be found. Newer manuals either Service and operating manuals. Radio amateurs should find this site a great source for ham radio equipment manuals. I will return to this site should I need information on any electrical equipment. priced easy to download in a PDF format and print pages need to undertake the repair.
 ;
Quality scan of the original. All the detail necessary to troubleshoot, repair and adjust the unit. I'm sure I will be downloading more manuals in the future as the need arises.
 ;
Exactly as described, a Service Manual complete with the schematics and PCB layout delivered in a timely manner. Many thanks for the great service.
 ;
some of the writing is a bit blur but the part in the schmatic was great and i have fixed the machine thanks
 ;
Well.. I'd searched for this manual and although I found many copies online I was pleased to find your website with a well balanced pricing system and easy to search and follow links. That together with the very quick response time was just what I was looking for.. being a very impatient tech.. ;-) I had the service manual in front of me within a short time.
Bookmarked.. and you can bet I will always come here first for my service & user manuals..
best regards
Ed(Tony) Foley
G7WHK
1
2
3
4
DELAY ADJUSTMENT OF THE CONTROL SIGNAL (SUS-D)
A
1 Measure the pulse width of the SUS-D signal. 2 Check the pulse width of the SUS-D input signal for the DK module. Adjust the variable control so that the pulse width of the SUS-D input signal for the DK module becomes the "pulse width of the SUS-D signal ± 5 nsec." Note: For details on measuring points of waveform, see the figure below.
SUS-D pulse width Tsus-D
B
50 % of the crest value SUS-D signal (input to the DRIVE Assy)
50 % of the crest value
SUS-D pulse width Tsus-Dg
50 % of the crest value
C
50 % of the crest value
SUS-D signal (input to the DK module)
D
SUS-D pulse width: Tsus-Dg Adjust so that "Tsus-Dg = Tsus-D ± 5 nsec," using the variable control shown in the table below:
Assy Y MAIN DRIVE
VR VR2002
E
F
126
1 2
PDP-5071PU
3 4
|
|
 |
> |
|