Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Another excellent buy! A fully readable PDF archive. Good prints!!
 ;
It is wonderful done!!! a great job in scanning the manual. Superior quality in all the electric scheme. Very understandable and net!!! Thank you!
 ;
muy buen manual por lo completo de este algunos esquemas estan muy divididos lo que hace algo dificil el seguimiento.
 ;
very good manual, with detail and clarity in esquematic diagrams and waveforms .
 ;
Very quality copy of original service manual, which contains the circuit diagrams, PCB and lists of components, well as recommendation for calibration procedures of device, also everything else, that need for repair, tuning and use this oscilloscope.
All presented copies have high-resolution, so you can view all in detail.
This manual will very useful for simple owners and for repairers.
I recommend these manual, because myself is owner of Philips PM3216 and I need sometimes servicing these oscilloscope (principally calibrating).
Also, these document is an example of excellent design of technical documentation.
1
2
3
4
DELAY ADJUSTMENT OF THE CONTROL SIGNAL (SUS-D)
A
1 Measure the pulse width of the SUS-D signal. 2 Check the pulse width of the SUS-D input signal for the DK module. Adjust the variable control so that the pulse width of the SUS-D input signal for the DK module becomes the "pulse width of the SUS-D signal ± 5 nsec." Note: For details on measuring points of waveform, see the figure below.
SUS-D pulse width Tsus-D
B
50 % of the crest value SUS-D signal (input to the DRIVE Assy)
50 % of the crest value
SUS-D pulse width Tsus-Dg
50 % of the crest value
C
50 % of the crest value
SUS-D signal (input to the DK module)
D
SUS-D pulse width: Tsus-Dg Adjust so that "Tsus-Dg = Tsus-D ± 5 nsec," using the variable control shown in the table below:
Assy Y MAIN DRIVE
VR VR2002
E
F
126
1 2
PDP-5071PU
3 4
|
|
 |
> |
|