There are currently no product reviews.
 ;
This manual was very clear and complete, the prices can't be beat, great to have older manuals available!
 ;
Doubted for buy this manual as it is my first order here and at not have cover image, I assumed would haven't. However, within 24 hs, already possessed the link to download it. The manual are scanned correctly and have all what is needed. Includes adjustments and diagrams of all circuits. Very satisfied.
 ;
Really good quality, аll readable.! Wonderful work shop. I recommend to all!
 ;
Good quality service manual.The scheme is on A3 format and very readable.Thank you
 ;
Very good service-manual with clear electrical diagrams. Thanks you.
1
2
3
4
A
DELAY ADJUSTMENT OF THE CONTROL SIGNAL (SUS-D)
1 Measure the pulse width of the SUS-D signal. 2 Check the pulse width of the SUS-D input signal (gate terminal of Q2112). Adjust the variable control so that the pulse width of the SUS-D input signal (gate terminal of Q2112) becomes the same pulse width ± 5 nsec as the SUS-D signal. Note: For details on measuring points of waveform, see the figure below.
B
SUS-D pulse width Tsus - D
50 % of the crest value SUS-D signal (input to the DRIVE Assy)
50 % of the crest value
SUS-D pulse width Tsus - Dg
C
50 % of the crest value SUS-D signal (input to the gate terminal of Q2112)
50 % of the crest value
D
SUS-D pulse width: Tsus - Dg Adjust so that "Tsus - Dg = Tsus - D ± 5 nsec," using the variable control shown in the table below:
Assy Y DRIVE Assy
VR VR2001
E
F
136
1 2
PDP-5080HD
3 4
|