Manual is in German but complete. I needed this one to fix a long lasting problem with the internal PSU of the camera. Most of the capacitors begin to leak after a few years wich results in the inability to power on the camera. When you try to turn it on the power led flickers and the unit directly turns off. Thanks to this manual I was able to locate all bad cap's and to dis- and reassemble the camera without any problems.
Text excerpt from page 134 (click to view)
1
2
3
4
A
Recovery flowchart (1-2)
[From the Recovery flowchart (1-1)]
Display RST MASK 09 (red 2). / [MKS S59] Note: Disregard the discharge that may appear during voltage-change setting.
Set VOL OFFSET to the setting value 240. / [VOF 240] Gradually decrease the VOL OFFSET value until disappear the discharge (dead cell).
B
� This setting becomes VOL OFFSET_max1.
VOL OFFSET_max1
Note: Make a note of this VOL OFFSET_max1 value.
VOL OFFSET_max1
107?
No
Replacement of abnormal circuits or re-replacement of the panel required
Yes Display RST MASK 10 (green 2). / [MKS S60]
Set VOL OFFSET to the setting value 240. / [VOF 240]
C
� This setting becomes Gradually decrease the VOL OFFSET value until disappear the discharge (dead cell). VOL OFFSET_max2.
VOL OFFSET_max2
Note: Make a note of this VOL OFFSET_max2 value.
VOL OFFSET_max2
107?
No
Replacement of abnormal circuits or re-replacement of the panel required VOL OFFSET_max
Yes Choose the lower value between VOL_OFFSET_max1 and VOL_OFFSET_max2, and set it as VOL_OFFSET_max.
D
[To the Recovery flowchart (1-3)]
Recovery flowchart (1-3)
[From the Recovery flowchart (1-2)]
Is the VOL OFFSET_max value minus the VOL OFFSET_min value greater than 96? Yes
E
No
Replacement of abnormal circuits or re-replacement of the panel required
Are the VOL OFFSET_max value 165 or greater and the VOL OFFSET_min value 069 or less? Yes Set VOL OFFSET to the setting value 117. / [VOF 117]
No
VOL OFFSET_max
165?
No
Yes Set VOL OFFSET to the setting value VOL OFFSET_max minus 48. Set VOL OFFSET to the setting value VOL OFFSET_min plus 48.
F
Determine the current VOL OFFSET setting value as the final value.