|
|
|
Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
I am satisfied with the service. And if need another manual, i will definitely buy from this site. Keep up the good work.
 ;
have download a number of manuals todate , most are excellant, one or two sometimes a little difficult to read but a least avaialable, great site .
Brad.
 ;
Excellent had everything I wanted, very happy with purchase
 ;
This service is relatively cheap, document is fast available, schematic is readable.
Thanks.
 ;
So far I´m a satisfied customer. I have only downloaded "TECHNICS SX-KN470 Service Manual" maybe I will use it later.
Best regards
Peter
1
2
3
4
A
Recovery flowchart (1-2)
[From the Recovery flowchart (1-1)]
Display RST MASK 09 (red 2). / [MKS S59] Note: Disregard the discharge that may appear during voltage-change setting.
Set VOL OFFSET to the setting value 240. / [VOF 240] Gradually decrease the VOL OFFSET value until disappear the discharge (dead cell).
B
� This setting becomes VOL OFFSET_max1.
VOL OFFSET_max1
Note: Make a note of this VOL OFFSET_max1 value.
VOL OFFSET_max1
107?
No
Replacement of abnormal circuits or re-replacement of the panel required
Yes Display RST MASK 10 (green 2). / [MKS S60]
Set VOL OFFSET to the setting value 240. / [VOF 240]
C
� This setting becomes Gradually decrease the VOL OFFSET value until disappear the discharge (dead cell). VOL OFFSET_max2.
VOL OFFSET_max2
Note: Make a note of this VOL OFFSET_max2 value.
VOL OFFSET_max2
107?
No
Replacement of abnormal circuits or re-replacement of the panel required VOL OFFSET_max
Yes Choose the lower value between VOL_OFFSET_max1 and VOL_OFFSET_max2, and set it as VOL_OFFSET_max.
D
[To the Recovery flowchart (1-3)]
Recovery flowchart (1-3)
[From the Recovery flowchart (1-2)]
Is the VOL OFFSET_max value minus the VOL OFFSET_min value greater than 96? Yes
E
No
Replacement of abnormal circuits or re-replacement of the panel required
Are the VOL OFFSET_max value 165 or greater and the VOL OFFSET_min value 069 or less? Yes Set VOL OFFSET to the setting value 117. / [VOF 117]
No
VOL OFFSET_max
165?
No
Yes Set VOL OFFSET to the setting value VOL OFFSET_max minus 48. Set VOL OFFSET to the setting value VOL OFFSET_min plus 48.
F
Determine the current VOL OFFSET setting value as the final value.
[To the main flowchart (1)]
134
1 2
PDP-5080XA
3 4
|
|
 |
> |
|