Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
This Service manual is very well scanned and its clean to read, no any anti-theft words that un-english could understand. I got my CCD600 working with this manual and it´s clear shematics :)
 ;
I was very pleased with the service provided and was surprised at how good the quality was of the manual. I thought it may be a third generation copy or so, but it is as good as the websites that charge 3 times this much. I repair some electronics for family and friends without charge, so this is perfect for me. Thank you very much.
 ;
The service was great and the document was also great. Highly recommend!!!!
If anyone has a users manual... Please email me. need one. $ [email protected]
 ;
I needed a service manual as the display on my oscilloscope was very dim. I thought I'd give owner-manuals.com a try, as they advertised a huge number of manuals. Sure enough they had one listed. I bought it hoping it would be useful... actually, I bought it hoping it would be readable! I've had manuals from online sources in the past, and been very disappointed. Not this time! An excellent manual, complete, and very readable. Using it I fixed my 'scope, and as such the manual was an investment that paid off manyfold. Do I have any complaints? One very minor one - The circuit diagrams could have been scanned at a higher resolution, as some of the details were a little difficult to make out - not impossible, just not as easy as my old eyes would like! Overall, I'm very satisfied with my manual, and I will certainly be using this company again. Well done.
 ;
I Have looked for this manual for quiet a while now, I have finally found it here. I believe this is the only place they have them in a very nice scan, pages are very clear to read, some of the pages are a bit tilted but overall it is great to have this manual available for purchase. Thanks
1
2
3
4
A
Trouble shooting of the A+6.5V output abnormal operation
This voltage Line is supplied to MAIN Assy from MAIN POWER SUPPLY Unit via DD Assy. Please check board to board connection first if A+6.5V is abnormal. e.g.) pin contact of connector, short between wire
From POWER SUPPLY unit
P12 CN304 (pin 1)
PV CN306 (pins 3 and 4)
To MAIN ASSY
B
From POWER SUPPLY unit
P8 CN302 (pin 1)
DD ASSY
Flowchart of Failure Analysis for The SLOT Power Supply
C
Failure analysis for the SLOT power supply Are 12V supplied to pins 1 and 2 of CN4001? Yes Are 16.5V supplied to pin 5 of CN4001? Yes Are 13.5V output from pin 3 of IC4003? Yes No No Failure in the DD Assy, POWER SUPPLY Unit or harness ADX3435 No Failure in the DD Assy or harness ADX3435
Failure in the IC4003
D
Are 3.3V supplied to pins 7 and 8 of CN4001? Yes Are 3.3V supplied to pin 11 of CN4001? Yes Failure analysis for the Each SLOT Input terminals
No
Failure in the DD Assy, POWER SUPPLY Unit or harness ADX3435
No
Failure in the DD Assy, POWER SUPPLY Unit or harness ADX3435
E
F
96
1 2
PDP-607CMX
3 4
|
|
 |
> |
|