Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Quick site processing. A complete and very useful manual with all details. Thank you!
 ;
Quick service response. A useful and very rare service manual with all details. I recomend this service.
 ;
I ordered this manual sometime in the afternoon and I received it on my e-mail the same evening.
This is a fantastically good and properly scanned copy of the original manual. All pages are of the same scale and they overlap each other. It means that you can print the manual and easily make it as a convenient paper manual.
The content of the manual is fantastic. Alignment descriptions, PCB layouts and elementary diagrams are explicit and precise. I immediately found what I was looking for. Thanks to this manual and Owner-Manuals.com my amplifier is alive again. Many thanx indded!
 ;
The manual was well-scanned and easy to read. As an added bonus, the Operator's Manual was bundled with the Service Manual!
I'd definitely use owner-manuals.com again.
 ;
Finally, i found one website, where i can download this service manual , and fix my hifi. The service manual is very good, and easy to download and to print.
1
2
3
4
A
Recovery flowchart (1-1)...Changing the VOL OFFSET setting
[From the Main flowchart (1)]
RST MASK 09 (Pink)
Gradually increase the VOL OFFSET value until disappear the discharge (lit cell). The VOL OFFSET value must be 101 or less.
B
Current VOL OFFSET > 096?
Yes
Replacement of abnormal circuits or re-replacement of the panel required
No Display RST MASK 18 (Red 626). / [MKR S18]
C
Set VOL OFFSET to the current setting value plus 123. / [VOF ���]
Is there erroneous discharge (abnormal dead cell)? (Check on the PANEL 1-ADJ menu.) No Display RST MASK 19 (Green 626). / [MKR S19]
Yes
Replacement of abnormal circuits or re-replacement of the panel required
D
Is there erroneous discharge (abnormal dead cell)? (Check on the PANEL 1-ADJ menu.) No Set VOL OFFSET to the current setting value minus 78. / [VOF ���]
Yes
Replacement of abnormal circuits or re-replacement of the panel required
Determine the current VOL OFFSET setting value as the final value.
E
[To the Main flowchart (1)]