Well.. I'd searched for this manual and although I found many copies online I was pleased to find your website with a well balanced pricing system and easy to search and follow links. That together with the very quick response time was just what I was looking for.. being a very impatient tech.. ;-) I had the service manual in front of me within a short time.
Bookmarked.. and you can bet I will always come here first for my service & user manuals..
best regards
Ed(Tony) Foley
G7WHK
I will definitely be back for more information when I need it.
Text excerpt from page 13 (click to view)
5
6
7
8
Main flowchart (2)...Checking VOL YNOFSA D
[From the Main flowchart (1)]
Display RST MASK 21 (Red 1023+). / [MKR S21]
A
Set VOL YNOFSA D to the tentative setting value 103. / [VYF 103]
Is there erroneous discharge (abnormal dead cell)? (Check on the PANEL 1-ADJ menu.) No Display RST MASK 22 (Green 1023+). / [MKR S22]
Yes
To the Recovery flowchart (2-1)
B
Is there erroneous discharge (abnormal dead cell)? (Check on the PANEL 1-ADJ menu.) No
Yes
To the Recovery flowchart (2-2)
C
Display RST MASK 15 (Magenta 120). / [MKR S15]
Set VOL YNOFSA D to the tentative setting value 151. / [VYF 151]
Is there erroneous discharge (abnormal lit cell)? (Check on the PANEL 1-ADJ menu.) No
Yes
To the Recovery flowchart (2-3)
Return the VOL YNOFSA D to the tentative setting value 128. / [VYF 128]
D
Determine the tentative setting value for VOL YNOFSA D as the final value.
From the Recovery flowchart (2-2) and (2-3)
[Adjustment completed]
E
Note: Make sure that the following values become the final setting values. VOL SUS *1 VOL XPOSF2 *1 VOL OFFSET VOL YNOFS1 D *1 VOL RST P *1 VOL YNOFS3 D *1 VOL XPOFS1 *1 VOL YNOFS4 D *1 VOL YNOFS4 A *1: The tentative setting value becomes the final value.
F