Press the UP/DOWN button to select the item CONT. Then Press UP/DOWN to adjust the waveform as Fig. 2. Then press Enter button to return. Gout
2.8+/-0.1V
Fig.2 6. Setup for oscilloscope as follows. CH1: 1V/div => TL45(Gout), CH2: 1V/div => TL44(Rout), Time: 10us/div, Trigger: TL1(VCOM), Falling Edge. Press the UP/DOWN button to select the item SBRTR. Then Press UP/DOWN to adjust the waveform as Fig. 3. Then press Enter button to return. Rout, Gout or Bout, Gout
7.
Fig.3 8. Setup for oscilloscope as follows. CH1: 1V/div => TL45(Gout), CH2: 1V/div => TL46(Bout), Time: 10us/div, Trigger: TL1(VCOM), Falling Edge. Press the UP/DOWN button to select the item SBRTB. Then Press UP/DOWN to adjust the waveform as Fig. 3. Then press Enter button to return. Setup for oscilloscope as follows. CH1: 1V/div ---, CH2: 1V/div => TL1(VCOM), Time: 10us/div, Trigger: TL1(VCOM), Falling Edge. Select the item VCOM. Then Press UP/DOWN to adjust the waveform as Fig.4. Adjust the voltage peak to the range of 5.6+/-0.1V. Then press Enter button to return. Press the UP/DOWN button to select the item DAC. Then to adjust the waveform is shown as fig. 4. The value is �1.7+/-0.1V. Then press Enter button to return. VCOM 5.6+/-0.1V -1.7+/-0.1V
9. 10.
11. 12.
Fig.4 13. 14. Press the UP/DOWN button to select the item H_POS. Then to set the green edge to center of LCD. Then press Enter button to return. Power off the camera after calibration. Remove the SD Card and AC Adapter cable.
13
|
|
 |
> |
|