|
|
|
Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Very Good! All the diagram are easy to read, and its complete.
 ;
This was an excellent source of detailed assembly information on a device which is at least 12 years old. A very lucky find, coupled with great service.
 ;
Excellent Service Manual and best price on the Internet. This Service Manual covers everything you could ever need including full circuit schematics, component layout diagrams, stripdown procedure and full parts list/breakdown. I needed this to carry out a modification to one of these headunits and this manual covered everything I needed. Fast delivery, processed within a few hours.
 ;
Thought I would never find a copy of the Technics SX-EN2 Service Manual until I found Owner-Manuals.com. Price was very fair and I received the download promptly. While a photocopy, it is quite readable and includes all the pertinent information and diagrams. Thank you Owner-Manuals!
 ;
I really like this manual and it's reliable.I found and bought easly.thank you.
PDR-555RW
6.5.4 Focus Bias Adjustment
Test Point Adjustment Point Adjustment Value
CN354 - pin 1 (RF) DIGITAL SYNCHRO button, RECORD button and REC MUTE button Adjust until RF jitter is minimal or that the eye pattern of the RF waveform is most open.
[Procedure]
(1) Press the DIGITAL SYNCHRO button in Stop mode. Note: Make sure the unit is in Stop mode. (2) Check that "48" appears on the FL display. (3) Press the AUTO/MANUAL button so that "04 34" appears on the FL display. (4) Press the FINALIZE button for focus-in. (5) Press the PLAY button for CAV-servo spindle kick. (6) Press the PAUSE button to close the tracking servo, then set the unit to Playback mode. (7) Adjust with the RECORD and REC MUTE buttons until the above adjustment value to be reached is obtained. Press the SET button to register the adjustment. Once the adjustment is registered with the SET button, "?" on the FL display will disappear. (8) Press the STOP button to stop the unit.
RF 10 : 1 VC 10:1 probe Jitter Meter or Oscilloscope
Note: Adjustment must be done around mid-radius on a disc.
54
|
|
 |
> |
|