Good scan of the original service manual. All schematics and adjustment procedures are there. It helped me to fix a long lasting problem with the tracking circuitry. The manual also includes the supplementals 1,2 and 3. Included are; electrical schematic's , pcb layout's, mechanical drawing's and exploded views, disassembly manual and maintenance procedures. 236 pages.
 ;
The Service Manual received was helpful. The electronic information is exactly what I needed.
I recomend all of my friends about this technical page.
 ;
High quality scan of service manual. I am satisfied!
 ;
Excellent copies.
I will use "Owner Manual" again a second time.
3. Electrical adjustment
Calibration Procedures � PDR-M65/M61
1. Equipments 1) Light Box: DNP Standerd Color Viewer Model: CCV51F Use Lamp: FL-10W-4 Voltage : 100V 2) Vector Scope 3) Focus Test Charts The Same Charts as M60. Near Focus : Supplied as Film Far Focus : Supplied as PDF file. File Name: farchart1.pdf, farchart2.pdf 4) Power Supply AC adaptor or DC power supply set to 5 V+ -0.05V. 5) Position ficture (Tripod)
2
CCD Calibration Tools: Power Supply (Topward: DC Power Supply set to 5V) DNP Light Box Camera Positioning Fixture Smart Media card with Calibration Code Procedure: 1. Install Smart Media card with Sierra Imaging Provided Calibration Code into camera. 2. Place camera into the positioning fixture camera lens should be no more than 1 cm from the surface of the light box.