Excellent Service Manual and best price on the Internet. This Service Manual covers everything you could ever need including full circuit schematics, component layout diagrams, stripdown procedure and full parts list/breakdown. I needed this to carry out a modification to one of these headunits and this manual covered everything I needed. Fast delivery, processed within a few hours.
 ;
Thought I would never find a copy of the Technics SX-EN2 Service Manual until I found Owner-Manuals.com. Price was very fair and I received the download promptly. While a photocopy, it is quite readable and includes all the pertinent information and diagrams. Thank you Owner-Manuals!
PDR-W739
6.5.4 Focus Bias Adjustment
Test Point Adjustment Point Adjustment Value Symptom when out of adjustment [Procedure]
(1) Press the SYNCHRO button in Stop mode. Note: Make sure the unit is in Stop mode. (2) Check that "OPT" disappears on the FL display. (3) Press the AUTO SPACE button so that "CDR 04ff34��" appears on the FL display. (4) Press the FINALIZE button for focus-in. (5) Press the PLAY/PAUSE 6 button for CAV-servo spindle kick. (6) Press the PLAY/PAUSE 6 button to close the tracking servo, then set the unit to Playback mode. (7) Adjust with the REC LEVEL knob until the above adjustment value to be reached is obtained. Press the REC LEVEL knob to register the adjustment. Once the adjustment is registered with the REC LEVEL knob, " ERASE " on the FL display will disappear. (8) Press the STOP button to stop the unit. CN102 - pin 1 (RF) SYNCHRO button, REC LEVEL knob Adjust until RF jitter is minimal or that the eye pattern of the RF waveform is most open. Sound broken, record characteristics deteriorate
RF 10 : 1 VC 10:1 probe Jitter Meter or Oscilloscope
Note: Adjustment must be done around mid-radius on a disc.
69
|
|
 |
> |
|