Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
I was having a hard time finding the problem with this Mackie 1604 unit. I didn't have a schematic. Went looking on the web and found your site and the price was more then reasonable. Ordered it and within the hour had the manual and within 15 minutes had the unit fixed. Best $4.99 I ever spent. Thank you.
Doug
 ;
This is a service manual in every sense of the word ( French and German versions of the text are included, as well as English..)
There are explanations of the mechanical and electrical functions, plenty of mechanical drawings, and the needed schematics. The quality of the scanning is excellent - all the component values are clearly legible - and very usefully there are pcb component layouts, so you can find a component on the schematic, and then very quicky pinpoint its physical location on the relevant pcb.
I cannot see how I can give this manual any less than the maximum 5 stars! Great value for money, which will pay for itself immediately. Excellent all round!
 ;
the manual is great and especially hard to find... thanks for the great service and having a hard to find manuel_
 ;
Please tell us what you think and share your opinions with others. Be sure to focus your comments on the product. You will receive $2.50 of store credit for Your review.
 ;
hat alles sehr gut geklappt. Das Servicemaual ist gut zu verwenden. Die Pläne und Schrift
ist klar und leserlich. Außerdem preiswert. Grüße an alle Hifi-Bastler
PDR-W739
6.5.4 Focus Bias Adjustment
Test Point Adjustment Point Adjustment Value Symptom when out of adjustment [Procedure]
(1) Press the SYNCHRO button in Stop mode. Note: Make sure the unit is in Stop mode. (2) Check that "OPT" disappears on the FL display. (3) Press the AUTO SPACE button so that "CDR 04ff34��" appears on the FL display. (4) Press the FINALIZE button for focus-in. (5) Press the PLAY/PAUSE 6 button for CAV-servo spindle kick. (6) Press the PLAY/PAUSE 6 button to close the tracking servo, then set the unit to Playback mode. (7) Adjust with the REC LEVEL knob until the above adjustment value to be reached is obtained. Press the REC LEVEL knob to register the adjustment. Once the adjustment is registered with the REC LEVEL knob, " ERASE " on the FL display will disappear. (8) Press the STOP button to stop the unit. CN102 - pin 1 (RF) SYNCHRO button, REC LEVEL knob Adjust until RF jitter is minimal or that the eye pattern of the RF waveform is most open. Sound broken, record characteristics deteriorate
RF 10 : 1 VC 10:1 probe Jitter Meter or Oscilloscope
Note: Adjustment must be done around mid-radius on a disc.
69
|
|
 |
> |
|