There are currently no product reviews.
 ;
muy buen manual por lo completo de este algunos esquemas estan muy divididos lo que hace algo dificil el seguimiento.
 ;
very good manual, with detail and clarity in esquematic diagrams and waveforms .
 ;
Very quality copy of original service manual, which contains the circuit diagrams, PCB and lists of components, well as recommendation for calibration procedures of device, also everything else, that need for repair, tuning and use this oscilloscope.
All presented copies have high-resolution, so you can view all in detail.
This manual will very useful for simple owners and for repairers.
I recommend these manual, because myself is owner of Philips PM3216 and I need sometimes servicing these oscilloscope (principally calibrating).
Also, these document is an example of excellent design of technical documentation.
 ;
Excellent printing quality.
A complete and very usefull service manual with all details.
GREAT SERVICE AT VERY LOW PRICE!
A+++++++++++++++++++++++++
 ;
manual excelente completo , diagramas y esquemas bien presentados y buena calidad de imagen.
PDR-W839
SETUP SEQUENCE (3CD)
POWER ON
FL display the time 0f 3CD
Any tray failing TOC READ? Yes Clamp the tray failing TOC READ (Doing TOC READ)
No
DISC on the clamped tary? Yes Start the timer PLAY
No
STOP (Clamping the tray)
Is there a DISC? No
Yes
About 15sec. passed after Power On? Yes
No
Start the timer PLAY
Other tray failing TOC READ? Yes
No
STOP (Clamping the tray)
Confirm the check point below when the sequnce does't work as above, or the 3CD does't work when pushing the key (OPEN/CLOSE key,PLAY key,etc).
Check Point
� Check the connection between 3CD CORE Assy and the MAIN Assy � Blow out micro-fuse (IC01) on the POWER SUPPLY Assy. � Check the logic of mechanism SW. (Refer to the "� Initialization sequence at POWER ON of 3CD MICRO CHANGER MECHANISM". � Check the select drive signal SELO+(CN1302 pin 8), SELO-(CN1302 pin 9) � Check the loading drive signal LO+(CN1302 pin 10), LO-(CN1302 pin 11)