This GRUNDIG UV5A Owner Manual is not only an instruction manual but a total functional circuit description of the Multimeter and includes circuit diagram at the end pages. It is very helpful for repairing and calibrating the instrument. It is written in two languages English and German for international support. It was very easy to repair my unit with this document. Regards, Regis Pauly, Electrical Engineer.
 ;
The owner's manual was evetything I thought it would be. I was able to print it out using both sides of the paper in quick order, saving me a search online for a used one.
 ;
Хорошее качество сканирования.
Мануал пришел часов эдак через 12. В целом доволен.
 ;
Fantastic quality and impressive delivery time. Based on this manual, I recommend this service without hesitation! Five Stars for certain.
 ;
Was happy to find the complete owners manual... It's all in there, just like the original...
5
Remove the lamp unit.
� Loosen the securing screws from the lamp unit. Hold the lamp unit by the handle and pull it in the direction of the arrow. At this time, keep the lamp unit horizontal and do not tilt it.
Handle
6
Insert the new lamp unit.
� Press the lamp unit firmly into the lamp unit compartment. Fasten the securing screws.
Securing screws
7
Replace the filter/lamp unit cover.
� Align the tab on the filter/lamp unit cover (1) and place it while pressing the tab (2) to close it. Then tighten the user service screw (3) to secure the filter/ lamp unit cover.
3 1 2
Info
� If the lamp unit and filter/lamp unit cover are not correctly installed, the power will not turn on, even if the power cord is connected to the projector.
User service screw
Resetting the Lamp Timer
Reset the lamp timer after replacing the lamp.
1 2
Connect the power cord.
� Plug the power cord into the AC socket of the projector.
AC socket
Reset the lamp timer.
� While simultaneously holding down and on the projector, press
Power ON button
and on the projector. � �LAMP 0000H� is displayed, indicating that the lamp timer is reset.
Volume buttons AUTO SYNC button
Appendix
Info
� Make sure to reset the lamp timer only when replacing the lamp. If you reset the lamp timer and continue to use the same lamp, this may cause the lamp to become damaged or explode.