|
|
|
Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Great copy of the manual, has all information required for servicing,
 ;
I work at an authorized service center and I can tell if a manual is as it should be. This one is. It may be a scan, but a very good one at that. The interesting part for me was the curcuit diagram which was scanned at high quality, making it as good as the original. I will definitely be back as a customer. I need not say this, but I will: the price was the best. Thank you owner-manuals.com .
 ;
really a very good manual even sometimes the quality is no so good as before still very readible and very very useful!
 ;
FAST very good and clear a great unexpensive job!!! very recomended for all people who are preofessional or hobbists as me!!!!!!
 ;
Thank you very much for this Service Manual, it helped us a lot to repair the M-4318!
...BUT: The parts list is missing and the free parts katalog on web isn't complete, so now we don't know the part numbers of the defect parts :(
We had to build them out of a working machine, and need the numbers to reorder the missing parts now.
SECTION 4 ADJUSTMENTS
4-1. MECHANICAL ADJUSTMENTS
TAPE RECORDER SECTION
PRECAUTION
Record/Playback/Erase Head Azimuth Adjustment Procedure : 1. Mode : FWD playback
test tape P-4-A100 (10kHz, �10dB) 47K � set LINE OUT (JK301) level meter
1. Clean the following parts with a denatured-alcohol-moistened swab : record/playback/erase head pinch roller rubber belts capstan 2. Demagnetize the record/playback/erase head with a head demagnetizer. 3. Do not use a magnetized screwdriver for the adjustments. 4. After the adjustments, apply suitable locking compound to the parts adjusted. 5. The adjustments should be performed with the rated power supply voltage unless otherwise noted. Torque Measurement
Torque Forward Forward Back Tension Reverse Reverse Back Tension FF/REW CQ-102RC CQ-102RC CQ-201B Torque Meter CQ-102C CQ-102C Meter Reading 36 to 61 g � cm (0.5 to 0.84 oz � inch) 2 to 6 g � cm (0.028 to 0.083 oz � inch) 36 to 61 g � cm (0.5 to 0.84 oz � inch) 2 to 6 g � cm (0.028 to 0.083 oz � inch) 61 to 143 g � cm (0.85 to 1.98 oz � inch)
2. Turn the adjustment screw for the maximum output levels. If these levels do not match, turn the adjustment screw until both of output levels match together within 1dB.
L-CH peak within output 1 dB level
within 1 dB
Screw position
R-CH peak
screw position L-CH peak R-CH peak
Tape Tension Measurement
Mode FWD REV Tension Meter CQ-403A CQ-403A Meter Reading more than 100g (more than 3.53 oz) more than 100g (more than 3.53 oz)
3. Phase Check Mode : FWD playback
test tape P-4-A100 (10kHz, �10dB) L-CH 47K � Osilloscope
set
V
H
4-2. ELECTRICAL ADJUSTMENTS
TAPE RECORDER SECTION 0dB = 0.775V
R-CH
47K � LINE OUT (JK301) screen pattern
1. The adjustnemts should be performed in the order in the service manual. (As a general rule playback circuit adjustment should be completed beforeming recording circuit adjustment.) 2. The adjustments should be performed for bothe L-CH and RCH unless otherwise indicated. Standard Intput Level
Input terminal source impedance input signal level LINE IN 10k� 0.5V (�3.8dB)
in phase 45° good
90°
135°
180°
wrong
4. Change the reverse playback mode and repeat the step 1 to 3. 5. After the adjustment, lock the adjustment screw with suitable locking compound. Adjustment Location : � record/playback/erase head �
Standard Output Level
Output terminal load impedance output signal level LINE OUT 47k� 0.5V (�3.8dB)
Test Tape
Type P-4-A100 WS-48B Signal 10kHz, �10dB 3kHz, 0dB Used for Azimuth Adjustment Tape Speed Adjustment
FWD side
REV side
adjustment screw
� 16 �
 $4.99 PMCDR50 SONY Owner's Manual Complete owner's manual in digital format. The manual will be available for download as PDF file aft…
|
|
 |
> |
|