Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Yes thank you i got the file i was after. There was a slight problem in my communication but it all worked out well.
A job well done.
 ;
Great manual...really saved me. The only problem is that I thought I would be able to download it directly when I paid for it but never received the download instructions until the next morning. The board trace pages were somewhat light also: really need to turn up the contrast on the printer before printing them. The schematic page was great; very clear! Well worth the money.
 ;
I've been in the electronic business for a long time. I used to buy Sam's Photofact for my needs which intailed having to go to the store and paying about $20 for a package of 3 different units so I was forced to buy more than I needed just to get one.
Owner manual is just at your keyboard and the information is almost instantansouly and the cost is very reasonable. Easy to print out if needed or simply read off of the screen. The larger the screen the better for obvious reasons.
 ;
Very good manual, at a very good price. Received in a timely manner
 ;
Only thу cover has poor quality, internal material has excellent quality - exactly what I needed
Thanks!
SECTION 4 MECHANICAL ADJUSTMENTS
PRECAUTION
1. Clean the following parts with a denatured-alcohol-moistened swab : record/playback head pinch roller erase head rubber belts capstan idlers 2. Demagnetize the record/playback head with a head demagnetizer. (Do not bring the head magnetizer close to the erase head.) 3. Do not use a magnetized screwdriver for the adjustments. 4. After the adjustments, apply suitable locking compound to the parts adjusted. 5. The adjustments should be performed with the rated power supply voltage unless otherwise noted. Torque Measurement Mode FWD FWD Back Tension FF REW Torque meter CQ-102C CQ-102C Meter reading 30 � 70 g � cm (0.42 � 0.97 oz � inch) 1.5 � 5.5 g � cm (0.021 � 0.076 oz � inch) more than 60 g � cm (more than 0.83 oz � inch) more than 60 g � cm (more than 0.83 oz � inch)
SECTION 5 ELECTRICAL ADJUSTMENTS
TAPE SECTION 0 dB = 0.775 V
� Standard Output Level Output terminal load impedance output signal level � Test Tape Type WS-48A Signal 3 kHz, 0 dB Used for tape speed adjustment HP OUT 32 � 0.25 V (�10 dB)
Tape Speed Adjustment Procedure: Mode: playback
test tape WS-48A (3 kHz, 0 dB) 32 � set digital frequency counter
CQ-201B CQ-201B
phones jack (J302)
Tape Tension Measurement Mode FWD Tension meter CQ-403A Meter Reading more than 100 g (more than 3.53 oz)
Adjust so that the value on the digital frequency counter is 3,000 Hz. Specification Value: Digital frequency counter 2,985 to 3,015 Hz Adjust so that the frequency at the beginning and that at the end of tape winding are between 2,955 to 3,045 Hz. Adjustment Location:
TAPE SPEED Adjustment
� 12 �
|
|
 |
> |
|