Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
I was at first dubious about payiong for downloaded manuals but having done so, I was extremely impressed with quality of the two manual I ordered, well worth the small price I paid.
I would highly recommend these to my friends.
 ;
reasonable price for the schematic - the service is perfect, all as expected and pointed by instructions - good scan of the original plans - thank you!
 ;
Manual was just as described!!! I odered it and in less than a day was able to download it and the text was clear and pages were all complete just as the original manual was. Purcashed this for a friend and they were more than happy. Perfect all around!
 ;
Excellent service and prompt delivery. But it's not a manual - only 4 pages wiring diagrams.
Thanks.
 ;
The manual I purchased was exactly what I needed to repair my Toshica television. The manual contained schematics and troubleshooting information that was very helpful.
5
6
7
8
A
For Diagnosis
For PRO-141FD
Terminal panel ELT
1 2
Remove the two screws. (BPZ30P080FTB) (KRP-600M only) Remove the two hexagon headed screws. (ABA1382)
2
�2
Terminal panel MTR
For KRP-600M
2
�2
1
1
B
Support bracket MTR
3 4 5
Remove the four screws. (PMB30P060FNI) Temporarily tighten one of the screws that was removed in Step 3. Disconnect the flexible cable from the MAIN Assy.
4
3
3
5 3
MAIN Assy I/O Assy
C
3
6 7
Remove all the cables that are connected to the I/O Assy from their clamps. Remove the cables that are connected to the CN1201 connector from their clamps.
6
6 A 6
CN1201
7 7
D
Note: In a case where the ambient temperature is 35 °C or less You can reverse the I/O Assy in Step 8 without removing the cables from their clamps in Step 7 above, if you detach the CN1201 connector from the I/O Assy and remove the cables connected to the connector from Clamp A.
8
Detach the I/O Assy with support bracket MTR attached. Reverse the I/O Assy in the direction shown in the photo below:
9
Hook support bracket MTR onto the temporarily tightened screw then reconnect the flexible cable to the MAIN Assy.
9
E
8
I/O Assy
Support bracket MTR
I/O Assy
F