|
|
|
Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Great tape deck manual!
I'm very positively surprised, because it is a very long manual, lot of pages, drawings, diagrams, description of how to make the alignment and adjustment procedures.
It is as good as the old "Naka" manuals from the 1970's - if somebody have seen them, they know what I mean by that.
I recommend to buy this very much !
 ;
I am a vintage hifi collector. No way to fix that device without the appropriate service manual...thanks to your site I got it and every thing is easier now. I got the manual right after ordering: fast cheap accurate ... thank you
 ;
Wonderful job clear. Qick fantastic. These people are really good. If even a problem arise they are wonderful assisting you. These scheme is so net despite this is a very old TV. Thank you for everything!!!!!!!!
 ;
Detailed schematic diagram, manual for professionals
 ;
Good service manual,exploded view,adjusment and test point locations,head alignment,mechanical checks and adjusments,all perfect.
5
6
7
8
6.3 METHOD FOR REPLACING THE SERVICE PANEL ASSY
A
When the Panel Assy is replaced with one for service, the following adjustments are required:
Adjustments of Vofs voltage and Vyprst voltage
Enter the reference adjustment values for the Vofs voltage and Vyprst voltage that are written on the label attached to the panel for service. Note: Enter the values, using an RS-232C command or the Factory Menu.
AWU���� Vofs = 35V Vyprst = 270V Hour Meter Space H (Rear of the Panel) AWU���� Vofs = 35V Vyprst = 270V Hour Meter 1520 H Write in the value for the hour meter when the Panel is replaced (ex. 1520H).
B
Using an RS-232C command Enter a "PFY" command with Factory mode ON. Convert the adjustment voltage values written on the label attached at the rear of the Panel to an input command, referring to the conversion chart. (See the next page.) � Reference adjustment of the Vofs voltage: Ex. "Vofs = 35" � (Check the conversion chart.) Enter "VOF112." � Reference adjustment of the Vyprst voltage: Ex. 50-inch "Vyprst = 270 V" � (Check the conversion chart.) Enter "VRP055." (Note that the conversion charts for 50-inch and 43-inch Panels are different.) Using the Factory Menu
1 1 5 10 15 20 25 30 32 1 1 5 10 15 20 25 30 32
P AN E L
FAC T .
VD 1 � 1 1 6 01 � NT V � J HS 6 [ TBL 1 / 6 0 VS ]
P AN E L
FAC T . ADJ
VD 1 � 1 1 6 01 � NT V � J HS 6 [ TBL 1 / 6 0 VS ]
P AN E L � 1
5
C
5
10
10
15 16
P AN E L � 1
ADJ
(+)
15 16
VOL
RST
P
<=>
: 058
Select the main item "PANEL FACT." by pressing the MUTE key then enter Panel Factory mode by pressing the SET key. Using the 5/� keys, select "PANEL-1 ADJ" then press the SET key to enter the next lower nested layer. Select "VOL-OFFSET" or "VOL RST P" then enter a command value converted from the voltage value, using the 2/3 keys.
D
Clearing data on various histories of the Panel, such as those on the hour meter
� It is necessary to clear the data on the hour meter, etc. to match them to the actual driving hours of the Panel. � It is also necessary to clear the data on SD and PD, because the accumulated power-on time when a shutdown or powerdown occurred is recorded. Note: Clear the values, using an RS-232C command or the Factory Menu. There are two types of hour meters. Do not take the MR hour meter for the hour meter. Using an RS-232C command To acquire the accumulated power-on time of the product itself, use the "GS2" RS-232C command. 1 To clear the data on the hour meter (for the Panel) : CHM 2 To clear the data on the pulse meter : CPM 3 To clear the data on the SD history : CSD 4 To clear the data on the PD history : CPD
E
Using the Factory Menu See "7.1.7 HOW TO CLEAR HISTORY DATA."
F
PDP-436PE
5 6 7 8
57
|
|
 |
> |
|