|
There are currently no product reviews.
 ;
everything was fine - fast, readable, worth the price
 ;
I'm happy to get a manual from this rare old amp. The pdf is from good qualty.
 ;
very quick service and manual as described - would happily trade here again!
 ;
Fast Download,all pages present,an excellent copy.THis enabled to find the origional part numbers and chase them up. The cartridge is proving difficult to find but at least I know the origional part number.Thanks to all.
 ;
The manual was as described. Complete with parts list and technical information. Fast delivery.
PRO-720HD, PRO-620HD, PRO-520HD
Lens Assy (Red)
Lens Assy (Green) Lens Assy (Blue)
Before focus lens adjustment, loose the screw which has tightened. Slide the screen to right, and adjust the focus of the lens.
Notes: To assemble the screen, perform the above procedures in reverse order. After assembling it, verify that the right and left sides of the screen are positioned as shown in the figure.
Fit left side edge of the screen to center of cabinet hole.
Screen
6
Cabinet
Disconnect the Anode Cable
WARNING: Before disconnect the anode cable, turn off the power, unplug the AC plug and let the unit discharge for more than 1 minut.
Pull straight up Rubber Cover Anode Cable
Holding the rubber cover firmly, turn counterclockwise and check that the lock has been disengaged. FBT Note : When reconnecting the cable, proceed in the reverse order. After reconnecting, tug on the cable to check that it is secure.
213
|