This PDF is very comprehensive. It includes drawings, parts lists, schematics, pictures, PCB drawings, mechanical layouts, etc. for all three stackable equipment. The scans are good too. Easy to read and no smudges or black lines. I have no complaints. I will make this site my first stop for finding my service manuals.
 ;
This service manual includes drawings, schematics, exploded views, parts list, operating details, and more. Very good scans, very readable. The only thing that made it a 4 star rating was on approximately 4 scans only half of the page was scanned then the other half. I would have preferred the pages to be whole scans.
 ;
Good manual contains all it takes to update, repair,these types of mixers.Thanks.
Troubleshooting
6-2 Checkpoints by Error Mode
6-2-1 No Power
Symptom - The LEDs on the front panel do not work when connecting the power cord. - The SMPS relay does not work when connecting the power cord. - The power of the unit seems to be out of order.
The SMPS relay or the LEDs on the front panel do not work when connecting the power cord if the cables are improperly connected or the Main Board or SMPS is out of order. In this case, check the following: - Check the internal cable connection status inside the unit. Major Checklist - Check the fuses of each part. - Check the output voltage of SMPS. - Replace the Main Board.
Troubleshooting Procedures
Are the AC IN socket connector and the Main SMPS CN800 connected? Yes
No
The AC IN socket connector and the Main SMPS CN800 connected
Is the Fuse (F801S) of the Main SMPS Power Input Part blown? Yes
No
Replace Fuse (F801S)
Main SMPS CN804-1 Pin 3 : STB 5V Pin 8 PS-ON : Check to see if it is 0V Yes
No Replace the Main SMPS
Replace the Main Board