|
|
|
Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Great Service Manual, Very Complete, as advertised, Perfect, Thanks!
 ;
Good quality service manual.It has helped me to fix my FV1800,particularly for replacing the dial cord.The scheme is on A3 format and very readable.Thank.Olivier.
 ;
This manual is complete and very readable.It was a great help for my two ICF5800L.The first one had the dial cord broken,and without the service manual it is impossible to replace it.Thank.Olivier.
 ;
This is a top quality manual. You couldn't get better if you had the original and scanned it yourself. Best price on the net as well. Diagrams are clear and complete, text is sharp and easy to read. Granted you don't get the manual the second you click pay, but the few hours you have to wait for it to be available for download isn't a problem at all. This is a very reliable company.
Very VERY pleased with the product, and will buy others. Thanks!
 ;
In a word AWESOME.
I never expected the quality and abundant content that I got with this manual. Everything you'd ever want to know from a service perspective is found in this manual, along with... as a bonus, operating instructions on how to use the unit. WOW. Very impressed with the quality of the manual. You won't be disappointed if you're looking for the EVS900 service manual.
REPLACEMENT OF LAMP
Lamp Time Reset Procedure:
Be sure to reset the Lamp time to �0� after replacing the Lamp. 1. Plug in the AC Cord, and turn on the power by pressing the POWER button. 2. Press and hold the VOLUME DOWN button on the unit and the PIP key on the remote together for over 5 seconds in power on condition. When the reset is finished, the display as shown in Fig. 51 appears and the LAMP LED goes out.
Lamp Replacement Procedure:
1. Press the POWER button on the remote to turn off the power. 2. Wait for about 1 minute until the cooling fan stops. Note: The lamp cooling fan will continue to operate for about 1 minute after the power is turned off. Do not unplug the AC Cord from the outlet until the fan has stopped. Avoid interrupting the power by using circuit breakers or switchable power strips. 3. After the cooling fan has stopped, unplug the AC Cord from the outlet. Note: Please wait more than one hour before replacing the lamp. [ Forced cooling function ] If you need to replace the lamp more urgently: � The Projection display has a forced cooling feature. After the POWER button is turned OFF, and sometime during about the first minute of the normal cooling fan operation, press the VOLUME UP button on the unit and CH UP key on the remote at the same time for more than 5 seconds. The cooling fan will operate for about 10 minutes. 4. Remove the Front Cover L Unit from the latches. 5. Remove the Lamp Cover by loosening the 2 Screws.
L AMP T I ME WAS RE S E T TO 0 .
RECALL
EXIT
Fig. 5-1 Note: 1. If the Lamp time exceeds 5000 hours, when turning on the power (Lamp ON), the display as shown in Fig.5-2 appears for about 5 minutes and LAMP LED flashes.
THE LAMP NEEDS TO BE REPLACED, AND THE LAMP HOUR METER NEEDS TO BE RESET.
Lamp Cover Screw Screw
RECALL
EXIT
Fig. 5-2 2. Due to variation in the way each lamp is used, the lamp may need to be replaced before the maximum 5000 hour limit is reached. These variations include the number of times and the duration the lamp is lit, prolonged use in excess of 24 hours, and any mechanical shock the bulb may accidentally experience. In situations where the use of this product is critical we recommend keeping a spare bulb on hand. WARNING: The high-pressure lamp may explode if not properly handled. The lamp is hot immediately after use. Touching it directly may cause burns. Please allow the lamp to cool before handling or replacing the lamp unit. Avoid touching the glass portion of the bulb with your fingers. Natural oils from your skin can cause a �hot spot� to develop, which can cause the bulb to crack when it gets hot. In case the bulb is accidentally touched, the area should be carefully cleaned using isopropyl alcohol and a soft lint free cloth or cotton ball. Cautions for Lamp Unit Replacement: � Handle the removed old lamp unit carefully. If handled � � improperly, it may explode. Wear gloves when replacing the lamp unit. If replacing the lamp unit becomes necessary during the operation of the TV, follow the procedure below to turn off the power and wait until the lamp unit cools completely. Fig. 5-3 6. Loosen the 2 Screws on the Lamp. Then, pull the Lamp. Note: Because the Lamp may still be hot, use caution when handling.
Lamp Screw Screw
Fig. 5-4 7. Install the new Lamp, and tighten the 2 Screws. 8. Install the Lamp Cover securely, and tighten the 2 Screws. 9. Install the Front Cover L Unit. Note: After replacing the Lamp, use caution to reset the Lamp time.
|
|
 |
> |
|