Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Up to now you are the BEST! Prompt-efficient and so reasonable ! I have been after SONY service manual for quite some time !Thank you very much ! I can recomend your service to
all my collegagues ! V.Bergfield .
 ;
This is a very good quality print (scan) of the original SONY service manual. The original from Sony is on very thin paper. Nevertheless it is very clear and sharp and excellent readable. I'm very satisfied to have now this rare document. I've looking for it many years (infrequent). It contains very detailed circuit diagrams, exploded views, part lists, PCB view with good readable connection lines. Very recommended.
 ;
A complete manual with all the needed details of calibrations and service instructions about the radio receiver.
A big deal.
Many thanks !
 ;
Fast delivery and good quality copy. To be recommended
 ;
Excellent product, very clear print. Detailed circuit and assembly diagrams - this enabled me to repair my CD player with confidence. I highly recommend this site.
PT-AE900U / PT-AE900E
6.10. Removal of Analysis Block
1. Remove the lamp unit according to the section 6.9. "Removal of Lamp Unit". 2. Remove the A-P.C.Board block according to the steps 1 through 3 in the section 6.3. "Removal of A-P.C.Board". 3. Unscrew the 2 screws and remove the lamp unit terminal. 4. Unscrew the 1 screw and remove the thermofuse attachment. 5. Unscrew the 3 screws and remove the lamphouse.
9. Unscrew the 3 screws and remove the LCD duct.
6. Unscrew the 3 screws and remove the block of Analysis Block, LCD Block and Projection Lens Block.
6.11. Removal of LCD Block
1. Remove the A-P.C.Board block according to the steps 1 through 3 in the section 6.3. "Removal of A-P.C.Board". 2. Unscrew the 2 screws and remove the LCD block.
7. Unscrew the 2 screws and remove the LCD block. 8. Unscrew the 4 screws and remove the projection lens block (with shift mechanism).
6.12. Removal of Projection Lens
1. Remove the projection lens block according to the steps 1 through 8 in the section 6.10. "Removal of Analysis Block ". 2. Unscrew the 4 screws and separate the projection lens and the shift mechanism.